Rapid Immunochromatography on Fresh Intestinal Biopsy Is Highly Accurate in Detecting Intestinal Antitransglutaminase Antibodies

Author:

Lega Sara1,De Leo Luigina1,Ziberna Fabiana1,Grigoletto Veronica2,Gaita Bartolomea1,Giangreco Manuela1,Villanacci Vincenzo3,Bramuzzo Matteo1,Di Leo Grazia1,Not Tarcisio12

Affiliation:

1. Institute for Maternal and Child Health, I.R.C.C.S. “Burlo Garofolo,” Trieste, Italy;

2. University of Trieste, Trieste, Italy;

3. Institute of Pathology, Spedali Civili di Brescia, Italy.

Abstract

INTRODUCTION: Intestinal antitransglutaminase antibodies (I-anti-TG2) are a specific marker of celiac disease (CeD). The aim of this study was to evaluate the diagnostic accuracy of a novel application of an immunochromatographic assay referred to as Rapid_AntiTG2 to detect I-anti-TG2 on intestinal biopsy lysate. METHODS: Consecutive pediatric patients referred to a single center for elective upper endoscopy were enrolled. Biopsies were taken from duodenal bulb and distal duodenum. For each sampling site, 2 biopsies were analyzed for standard histology, 1 biopsy was cultured to perform the reference standard assay for I-anti-TG2 detection (endomysium [EMA] biopsy), and 1 biopsy was mechanically lysed to perform Rapid_AntiTG2. The primary outcome was the diagnostic accuracy of Rapid_AntiTG2 on biopsy lysate compared with that of the gold standard (serology + histopathology) for CeD diagnosis. The secondary outcome was the agreement of Rapid_AntiTG2 with EMA biopsy. RESULTS: One hundred forty-eight patients were included. Of them, 79 were those with CeD (64 classical CeD, 2 seronegative CeD, and 13 potential CeD) and 69 were controls. Rapid_AntiTG2 on biopsy lysate had very high diagnostic accuracy (sensitivity 100%, specificity 97%, LR+ 34.1, LR− 0.01) in separating patients with CeD from controls. Diagnostic accuracy was unchanged in patients with potential and seronegative CeD. Rapid_AntiTG2 on biopsy lysate had almost perfect agreement with the EMA biopsy reference test (99% agreement, Cohen K 0.97). DISCUSSION: I-anti-TG2 can be detected with an immunochromatographic assay after simple mechanical lysis of fresh intestinal biopsy with very high diagnostic accuracy. The test is quick and easy to perform and can be widely available in any endoscopy unit. Its implementation would allow a better understanding of the prognostic value of I-anti-TG2 and help clinicians in cases of suspected CeD that are difficult to classify.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Gastroenterology,Hepatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3