Use of Impedance Planimetry in the Diagnosis of Gastric Sleeve Stenosis: The Establishment of New Benchmark Values

Author:

Evans Gretchen1,Yu Jessica X.2,Moy Benjamin3ORCID,Leith Annelie3,Volk Sarah1,Taher Omar1ORCID,Miller Candice1ORCID,Schulman Allison R.14ORCID

Affiliation:

1. Division of Gastroenterology and Hepatology, University of Michigan, Ann Arbor, Michigan, USA;

2. Division of Gastroenterology and Hepatology, Oregon Health & Science University, Portland, Oregon, USA;

3. University of Michigan Medical School, Ann Arbor, Michigan, USA;

4. Department of Surgery, University of Michigan, Ann Arbor, Michigan, USA.

Abstract

INTRODUCTION: Gastric sleeve stenosis (GSS) is an increasingly common adverse event following sleeve gastrectomy for which objective diagnostic criteria are lacking. Impedance planimetry measurements show promise in characterizing GSS, though normal and abnormal benchmark values have never been established. METHODS: This was a retrospective analysis of upper endoscopies performed with impedance planimetry for suspected GSS. A bariatric endoscopist, blind to impedance planimetry measurements, assessed gastric sleeve anatomy and graded GSS severity. Impedance planimetry of diameter and distensibility index (DI) were obtained using 3 different balloon volumes (30, 40, and 50 mL). RESULTS: A total of 110 upper endoscopies were included. Distribution of GSS was graded as none, mild, moderate, and severe in 19 (17%), 27 (25%), 34 (31%), and 30 (27%) procedures, respectively. In normal gastric sleeve anatomy, mean (±SD) diameter and DI measurements using consecutive balloon volumes ranged from 19.1 (±5.5) to 23.2 (±1.7) and 16.8 (±4.9) to 23.1 (±10.9), respectively. In severe GSS, mean diameter and DI measurements ranged from 10.3 (±3.0) to 16.6 (±2.1) and 7.5 (±2.4) to 7.7 (±2.4), respectively. When stratified by severity, impedance planimetry measurements of diameter and DI were significantly lower with each subsequent increase in GSS grade regardless of balloon fill volumes (P ≤ 0.001). DISCUSSION: Impedance planimetry measurements provide objective assessment in the diagnosis of GSS and correlate with luminal narrowing. A diameter ≥20 mm and a DI ≥15 mm2/mm Hg, as measured by impedance planimetry, are predictive of normal gastric sleeve anatomy. This study provides new benchmark values for the diagnosis and severity of GSS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Gastroenterology,Hepatology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Obesity and GI Diseases: A Major Problem Weighing on Our Guts and Minds;American Journal of Gastroenterology;2024-06

2. Endoscopic Management of Post-Sleeve Gastrectomy Complications;Journal of Clinical Medicine;2024-03-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3