Applicability of the Platelia EIA® Aspergillus test for the diagnosis of aspergilosis in penguins

Author:

Cabana A. L.1,Xavier M. O.2,Mendes J. F.1,Teles A. J.1,Martins A. M.3,Silva-Filho R. P.2,Meireles M. C. A.1

Affiliation:

1. Universidade Federal de Pelotas, Brasil

2. Universidade Federal do Rio Grande, Brasil

3. Universidade Federal de Pelotas, Brasil; Universidade Federal do Rio Grande, Brasil

Abstract

Abstract Even today, an effective diagnostic test for aspergillosis in penguins is unknown, being the gold standard post-mortem examinations. The fungal antigen galactomannan (GM) has been used as a biomarker of disease in humans and is detected by the Platelia Aspergillus EIA (BioRad)®, a commercial kit based on the sandwich ELISA technique. It is standardized for use in neutropenic patients, however studies have demonstrated its usefulness also possible for birds. The aim of our study was to evaluate the effectiveness of Platelia Aspergillus EIA® test (BioRad-US) in the diagnosis of aspergillosis in Magellanic penguins, determining sensitivity, specificity, and positive and negative predictive values for different cut-off points. Were included in the study, blood serum samples (n = 29) Magellanic penguins in captivity that died by aspergillosis. Detection of GM was performed following manufacturer's instructions and the GM index was obtained by dividing the average value of OD of the duplicate of the clinical sample by duplicate OD of the average value of the cut-off sample provided by the kit. Through information database results were obtained for the presence of anti-Aspergillus fumigatus antibodies detected by agar gel immunodiffusion (AGID) for all serum samples. Results were analyzed using chi-square test and Kruskal-Wallis from SPSS 20.0, IBM®. ROC curve was obtained and from this, rates of sensitivity, specificity, positive and negative predictive values were also calculated based on four different cutoff points (0.5, 1.0, 1.5 and 2.0). The serum GM index did not differ between animals of the case and control group (pkw =0.097). In determining the ROC curve for serum GM detection the value of area under the curve was 0.635. From the values determined by the coordinate of the curve, four different cut points (0.5, 1.0, 1.5 and 2.0) were analyzed, resulting in sensitivity rates ranging from 86.2 to 34.5% % and specificity between 87% and 26.1%. By comparing the serum GM index in group case as the presence or absence of antibodies detected by AGID was found p=0.503. The detection of GM the Platelia Aspergillus EIA® test seems is not be useful for the diagnosis of aspergillosis in naturally infected penguins.

Publisher

FapUNIFESP (SciELO)

Subject

General Agricultural and Biological Sciences

Reference23 articles.

1. Assessment of a commercial sandwich ELISA in the diagnosis of aspergillosis in falcons;ARCA-RUIBAL B.;The Veterinary Record,2006

2. Comparison of the value of measurement of serum galactomannan and Aspergillus -specific antibodies in the diagnosis of canine sino-nasal aspergilosis;BILLEN F.;Veterinary Microbiology,2009

3. Monitoramento sorológico para diagnóstico precoce da aspergilose em pinguins em cativeiro.;CABANA A.L.,2013

4. Serological monitoring of antibodies for an early diagnosis ofaspergillosis in captive penguins;CABANA Â.L.;Pesquisa Veterinária Brasileira,2015

5. Galactomannan assay and plasma protein electrophoresis findings in psittacine birds with aspergillosis;CRAY C.;Journal of Avian Medicine and Surgery,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3