Maximum phonation time in the pulmonary function assessment

Author:

Moreno Edvania Gomes Henrique1ORCID,Calassa Bianca Teixeira1ORCID,Oliveira Daniela Vitoria Silva1ORCID,Silva Maylanne Iris Nascimento1ORCID,Albuquerque Laienne Carla Barbosa de Barros1ORCID,Freitas-Dias Ricardo de1ORCID,Silva Bruno Rafael Vieira Souza2ORCID,Araújo Rodrigo Capatto de2ORCID,Costa Eduarda Lubambo3ORCID,Costa Emília Chagas3ORCID,Correia Junior Marco Aurélio de Valois4ORCID

Affiliation:

1. Universidade de Pernambuco, Brazil

2. Universidade Federal de Pernambuco, Brazil; Universidade Federal da Paraíba, Brazil

3. Universidade Federal de Pernambuco, Brazil

4. Universidade de Pernambuco, Brazil; Universidade Federal de Pernambuco, Brazil; Universidade Federal da Paraíba, Brazil

Abstract

ABSTRACT Purpose: to evaluate the reliability of the maximum phonation time (MPT) and Vital Capacity intra and inter-examiner, by means of the single-breath counting test (CT) and the sustained /a/ phoneme, and the slow vital capacity (SVC). Methods: a reliability study carried out in three groups of healthy individuals, each group with 30 volunteers, allocated according to age. SVC was measured using a spirometer, while the MPT was assessed by the phoneme /a/ and CT. The data were analyzed using SPSS version 20.0. Initially, descriptive statistics were used and for data reliability, the intraclass correlation coefficient (ICC). Results: the Intraclass Correlation Coefficients (ICC) were considered excellent, with significant results above 0.92 for SVC and greater than 0.79 for CT and phoneme /a/. Regarding the inter-examiner evaluation, the ICCs were also significant for both SVC with values greater than 0.96, and for CT and the phoneme /a/ with values greater than 0.85. The error inherent in the technique was assessed using the standard error of the measurement for intra and inter-examiner analyses with values ranging from 1.79 to 3.29 for phoneme /a/, 3.20 to 6.58 for CT and 65, 05 to 206.73 for SVCml. Conclusion: phonation techniques with the phoneme /a/ and CT, as well as SVC, have an excellent reliability, due to intra and inter-examiner agreement measures.

Publisher

FapUNIFESP (SciELO)

Reference29 articles.

1. Importância da capacidade vital lenta na detecção de obstrução das vias aéreas;Barros ARG;J Bras Pneumol,2013

2. Comparison between reference values for FVC, FEV1, and FEV1/FVC ratio in white adults in Brazil and those suggested by the Global Lung Function Initiative 2012;Pereira CAC;J bras pneumol,2014

3. Standardisation of spirometry;Miller MR;Eur Respir J,2005

4. Pulmonary function tests for diagnosing lung disease;Heckman EJ;JAMA,2015

5. Correlation between slow vital capacity and the maximum phonation time in healthy adults Rev;Lima DCB;CEFAC,2014

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献