Thermal analysis of the muscle-bone interface in test samples after the use of therapeutic ultrasound

Author:

Nogueira Cinthya Kelly Bastos Freire1ORCID,Barbante Luara Mirella Bitencourt1ORCID,Coelho Karen de Almeida2ORCID,Souza Vanessa Lima de1ORCID,Pereira Wagner Coelho de Albuquerque2ORCID,Maggi Luis Eduardo1ORCID

Affiliation:

1. Universidade Federal do Acre, Brazil

2. Universidade Federal de Rio de Janeiro, Brazil

Abstract

Abstract Introduction Ultrasound used in diathermic therapies aims to achieve temperatures between 40 and 45 °C, since temperatures above 45 °C are known to cause tissue necrosis and burns. Many studies have been conducted to investigate the effect of therapeutic ultrasound in the presence of metallic implants, using phantoms (test samples) and in vivo and ex vivo animal models. In most of these studies, the ultrasound probe is fixed in one area, while in clinical practice, it is recommended that it be moved to avoid possible local overheating. Objective To analyze the thermal field at the muscle-bone interface in phantoms in the presence or absence of metallic implants after the application of therapeutic ultrasound. Methods Phantoms composed of layers simulating fat and muscle, and a layer of beef rib bone, with and without a titanium metallic implant, were prepared. The experiment involved different intensities (1.0, 1.5, and 2.0 W/cm2) and exposure times (5 and 10 minutes), common in clinics, with linear scanning of the probe. Results The experiments indicated that the muscle/implant interface heated less than the muscle/bone interface, especially at intensities of 1.5 and 2.0 W/cm2, after 5 and 10 minutes of treatment. Conclusion The results suggest the possibility of using therapeutic ultrasound in patients with metallic implants, encouraging future research to develop evidence-based protocols and safe recommendations in physiotherapy.

Publisher

FapUNIFESP (SciELO)

Reference20 articles.

1. Eletroterapia: prática baseada em evidências;Kitchen S,2003

2. Estudo do campo térmico do ultrassom terapeutico em phantom do terço medio do braço com e sem implantes metalicos;Oliveira DP,2013

3. Efeitos térmicos do ultrasom terapêutico sobre os tecidos ósseo e muscular e sobre placa metálica implantada: estudo experimental térmográfico em coelhos;Garavello I;Rev Bras Ortop,1997

4. A review of therapeutic ultrasound: effectiveness studies;Robertson VJ;Phys Ther,2001

5. Efeito do ultrassom terapêutico: Uma abordagem geral no aparelho e nas principais contra indicações;Alencar I,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3