Evaluation of the palatal bone in different facial patterns for orthodontic mini-implants insertion: A cone-beam computed tomography study

Author:

VIDALÓN José Antonio1ORCID,LIÑAN Carlos1ORCID,TAY Lidia Yileng1ORCID,MENESES Abraham1ORCID,LAGRAVÈRE Manuel2ORCID

Affiliation:

1. Peruvian Cayetano Heredia University, Peru

2. University of Alberta, Canada

Abstract

ABSTRACT Objective: Evaluate the height, thickness and cortical density of the palatal bone of adults with different vertical facial patterns using Cone-Beam Computed Tomography (CBCT). Methods: This study analyzed 75 CBCTs of patients between 18 and 35 years old (45 men and 30 women). The CBCTs were classified into three groups based on their facial pattern: normodivergent, hypodivergent and hyperdivergent as determined from lateral cephalograms synthesized from the CBCTs. The height, cortical thickness and cortical density of the palatal bone were measured at 4, 8, 12, 16 and 20mm posterior to the incisive foramen, and at 3, 6 and 9mm lateral to the midpalatal suture. ANOVA with Tukey post-hoc tests were used for analysis of the data, at significance level of p< 0.05. Results: The hypodivergent pattern had a significant difference and the greatest height and cortical thickness of the palatal bone, followed by the hyperdivergent and the normodivergent patterns. No significant differences were found in minimum and maximum values of cortical density. Conclusion: The palatal bone is a favorable anatomical area to install different orthodontic temporary anchorage devices (TADs), where individuals with the hypodivergent vertical facial pattern have a higher height and cortical thickness of the palatal bone, followed by the hyperdivergent pattern and finally the normodivergent pattern. No significant differences in the cortical density of the palatal bone in the three facial patterns were found.

Publisher

FapUNIFESP (SciELO)

Subject

Oral Surgery,Orthodontics

Reference30 articles.

1. Palatal bone thickness and associated factors in adult miniscrew placements a cone-beam computed tomography study;Poon Y;Kaohsiung J Med Sci,2015

2. Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement;Gracco A;Am J Orthod Dentofacial Orthop,2008

3. Evaluation of bone thickness of hard palate for orthodontic mini implant placement by cone beam computed tomography;Khademi S;Indian J Sci Res,2014

4. Anatomical guidelines for miniscrew insertion Palatal sites;Ludwig B;J Clin Orthod,2011

5. Alternative to the median region of the palate for place- ment of an orthodontic implant;Bernhart T;Clin Oral Implants Res,2000

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3