Unenhanced magnetic resonance angiography as an accurate alternative in the preoperative assessment of potential living kidney donors with contraindications to computed tomography angiography and to contrast-enhanced magnetic resonance angiography

Author:

Velloni Fernanda Garozzo1ORCID,Cardia Patrícia Prando2ORCID,Torres Ulysses dos Santos3ORCID,Pereira Marco Antonio Haddad1ORCID,Penachim Thiago José4ORCID,Favaro Larissa Rossini5ORCID,Ramalho Miguel6ORCID,D’Ippolito Giuseppe7ORCID

Affiliation:

1. Universidade Federal de São Paulo, Brazil; Diagnósticos da América SA, Brazil

2. Universidade Federal de São Paulo, Brazil; Centro Radiológico Campinas, Brazil

3. Grupo Fleury, Brazil

4. Centro Radiológico Campinas, Brazil

5. Universidade Federal de São Paulo, Brazil

6. Hospital Garcia de Orta, Portugal

7. Universidade Federal de São Paulo, Brazil; Grupo Fleury, Brazil

Abstract

Abstract Objective: To evaluate the accuracy of steady-state free precession (SSFP) unenhanced magnetic resonance angiography (MRA) at 1.5 T for the identification of multiple renal arteries, using computed tomography angiography (CTA) as the reference standard. Materials and Methods: This was a prospective study involving 39 patients (26 males; mean age, 62.6 years) who underwent CTA and unenhanced MRA to evaluate the proximal and middle segments of the renal arteries. The analysis was performed in two phases: the quality of unenhanced MRA images was classified as diagnostic or nondiagnostic for the presence of multiple renal arteries by two independent readers; two other independent readers then evaluated the images previously classified as being of diagnostic quality. The sensitivity, specificity, and overall accuracy of unenhanced MRA were calculated, CTA being used as the reference standard. The kappa statistic was used in order to calculate interobserver agreement. Results: The image quality of unenhanced MRA was considered diagnostic in 70-90% of the extrarenal arterial segments. The CTA examination revealed 19 multiple renal arteries (8 on the right and 11 on the left). The accuracy of unenhanced MRA for the identification of multiple renal arteries was greater than 90%, with a sensitivity of 72.7-100% and a specificity of 96.3-100%. Conclusion: Unenhanced MRA provides high quality imaging of the extrarenal segments of renal arteries. This method may be used as an alternative for the evaluation of the renal arteries, given that it has an accuracy comparable to that of CTA.

Publisher

FapUNIFESP (SciELO)

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3