COMPARISON OF METHODS FOR EVALUATING UPPER LIMB STRENGTH BY HAND-HELD DYNAMOMETRY

Author:

Nepomuceno Júnior Balbino Rivail Ventura1ORCID,Menezes Manoela Porto dos Santos2ORCID,Santos Kamilla Ribeiro Bastos dos2ORCID,Gomes Neto Mansueto2ORCID

Affiliation:

1. Universidade Federal da Bahia, Brazil; Universidade Federal da Bahia, Brazil

2. Universidade Federal da Bahia, Brazil

Abstract

ABSTRACT Introduction The upper limbs are segments of the human body responsible for primary activities of daily life, and the muscles are essential structures for performing these activities. There have been few studies on intra- and inter-examiner reliability of the hand-held dynamometer (HHD) in healthy subjects, and none have been published that compare dynamometric evaluation methods in the main muscles in this segment. Objective Evaluate intra-examiner and inter-examiner assessment reliability of the hand-held dynamometry of upper limb muscles in healthy individuals, as well as comparing the assessment reliability between fixed and non-fixed methods. Methods Healthy subjects aged over 18 years were recruited for the study. The isometric contraction for ten muscle groups of the dominant upper limb was tested. For the fixed method, we used a system of suction cups, connected to the HHD by an inelastic belt. For the non-fixed method, the examiner supported the device by hand. The isometric contraction was sustained for three seconds. Each measurement was repeated three times, considering the highest value obtained. The reliability was calculated using the intraclass correlation coefficient (ICC). The dispersion between measurements was expressed by a Bland-Altman plot. Results The sample consisted of 25 volunteers, all right-handed. The intra-examiner ICC was 0.89-0.99 for the non-fixed method, and 0.43 to 0.85 for the fixed method. Inter-examiner reliability showed equivalent behavior. This study showed that evaluation of upper limb muscle strength using an isometric dynamometer has excellent intra-examiner and inter-examiner reliability. The supine position was chosen due to the need to propose a feasible protocol for clinical practice that could be replicated for the majority of publics and in different environments. The non-fixed method showed better reliability overall, demonstrating the feasibility of this tool without the need for adaptations, additional devices, or increased operating costs for this evaluation. Conclusion Comparison between the fixed and non-fixed HHD methods demonstrated superiority of the non-fixed method in terms of reliability. Level of evidence II; Investigation of a diagnostic exam - Development of diagnostic criteria with consecutive patients.

Publisher

FapUNIFESP (SciELO)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference25 articles.

1. Sarcopenia: revised European consensus on definition and diagnosis;Cruz-Jentoft AJ;Age Ageing,2019

2. Funcionalidade e incapacidade: aspectos conceptuais, estruturais e de aplicação da Classificação Internacional de Funcionalidade, Incapacidade e Saúde (CIF);Fontes AP;Rev Port Saúde Pública,2010

3. Relationship between grip strength and global muscle strength in community-dwelling older people;Porto JM;Arch Gerontol Geriatr,2019

4. Longitudinal Changes in Muscle Mass and Function in Older Men at Increased Risk for Sarcopenia - The FrOST-Study;Kemmler W;J Frailty Aging,2019

5. Intraexaminer reliability of hand-held dynamometry in the upper extremity: a systematic review;Schrama PP;Arch Phys Med Rehabil,2014

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献