CORRELATION BETWEEN THE SCHANZ SCREW INSERTION ANGLE AND THE LOSS OF KYPHOSIS CORRECTION IN THORACOLUMBAR FRACTURES

Author:

VIEIRA FABIO ANTONIO1ORCID,GARCIA ANDRÉ SOUSA1ORCID,UETA FERNANDO TADASHI SALVIONI1ORCID,CURTO DAVID DEL1ORCID,UETA RENATO HIROSHI SALVIONI1ORCID,PUERTAS EDUARDO BARROS1ORCID

Affiliation:

1. Universidade Federal de São Paulo, Brazil

Abstract

ABSTRACT Objective To compare the Schanz screw insertion angle and the loss of the regional kyphosis correction in thoracolumbar burst fractures following posterior short instrumentation surgery. Methods Patients with a thoracolumbar burst fracture between levels T11-L2 were divided into two groups (parallel and divergent) according to the angle formed between the Schanz screw and the vertebral plateau. Regional kyphosis was evaluated in preoperative, immediate postoperative and last follow-up radiographs. Results Of the 58 patients evaluated, 31 had a parallel assembly and 27 had a divergent assembly. When we analyzed the angle of kyphosis, no statistical difference was observed between the pre- and postoperative radiographs. However, a statistical difference in the last follow-up radiographs and in the final loss of the kyphosis correction was confirmed. Conclusion The insertion of Schanz screws with a divergent assembly presents better radiographic results with less loss of kyphosis correction angle when compared with the parallel assembly technique. Level of Evidence III; Retrospective cohort study.

Publisher

FapUNIFESP (SciELO)

Subject

Clinical Neurology,Orthopedics and Sports Medicine,Surgery

Reference40 articles.

1. Clínica ortopédica;Defino HLA,2000

2. Treatment of thoracolumbar burst fractures with variable screw placement or Isola instrumentation and arthrodesis: case series and literature review;Alvine GF;J Spinal Disord Tech,2004

3. Factors influencing the quality of life after burst fractures of the thoracolumbar transition;Briem D;Arch Orthop Trauma Surg,2004

4. Treatment of unstable thoracolumbar and lumbar spine injuries using Cotrel-Dubousset instrumentation;Katonis PG;Spine (Phila Pa 1976),1999

5. Transpedicle body augmenter: a further step in treating burst fractures;Li KC;Clin Orthop Relat Res,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3