Tooth-size discrepancy: A comparison between manual and digital methods

Author:

Correia Gabriele Dória Cabral1,Habib Fernando Antonio Lima2,Vogel Carlos Jorge3

Affiliation:

1. Federal University of Bahia

2. UFBA

3. University of São Paulo

Abstract

INTRODUCTION: Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. OBJECTIVE: This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. MATERIAL AND METHODS: To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. RESULTS: Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. CONCLUSIONS: Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable.

Publisher

FapUNIFESP (SciELO)

Subject

Oral Surgery,Orthodontics

Reference27 articles.

1. The Accuracy and Reliability of Measurements Made on Computer-Based Digital Models;Quimby ML;Angle Orthod,2004

2. Análise de modelos ortodônticos pelo método digitalizado;Matsui RH;Rev Inst Ciênc Saúde,2007

3. Confiabilidade do uso de modelos digitais tridimensionais como exame auxiliar ao diagnóstico ortodôntico: um estudo piloto;Oliveira DD;Rev Dental Press Ortod Ortop Facial,2007

4. Digital models: a new diagnostic tool;Redmond WR;J Clin Orthod,2001

5. Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models;Zilberman O;Angle Orthod,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3