Micrographic evaluation of different widia compositions of orthodontic pliers submitted to peracetic acid and intensive use

Author:

MARCIAL Érika Zoli1ORCID,NEVES José Guilherme2ORCID,CORRER-SOBRINHO Lourenço2ORCID,MENEZES Carolina Carmo de1ORCID,GODOI Ana Paula Terossi de1ORCID,VEDOVELLO FILHO Mário1ORCID,COSTA Ana Rosa3ORCID

Affiliation:

1. Uniararas, Brasil

2. Universidade Estadual de Campinas, Brasil

3. Uniararas, Brasil; Universidade Estadual de Campinas, Brasil

Abstract

Abstract Introduction The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two alloy compositions subjected to the action of 0.2% peracetic acid and intensive use. Material and method Twenty distal cutting pliers were divided into two groups (n=10) according to widia composition (%wt): W1- 85% to 87% of tungsten carbide (TC) and other components in the proportion of 13% to 15% and W2 – 87.5% to 88.5% of tungsten carbide and 11.5% to 12.5% for other components. All the pliers were assessed in a stereoscopic magnifying glass (32x) after three treatments: before use (T0); after cutting 100 segments of rectangular stainless-steel wires – intensive use (T1); and after 100 sterilization cycles in 0.2% peracetic acid and intensive use (T2). The cutting sites of all pliers were standardized. Widia regions were defined by line “A” representing T1 and line “B” representing T2. A frequency distribution table and Fisher’s exact test (α=0.05) was performed. We assessed two widia from each composition and treatment in SEM and energy-dispersive X-ray spectroscopy (EDS/SEM). Result The results showed that W1 pliers presented significantly fewer defects after the sterilization cycles with peracetic acid and intensive use than W2 pliers (p=0.0198). There were no differences between both pliers after intensive use (p=1.000). Conclusion The SEM images and EDS analyses showed changes in widia surfaces after the different treatments. Widia composition affected the resistance of the orthodontic pliers after sterilization cycles with 0.2% peracetic acid and intensive use.

Publisher

FapUNIFESP (SciELO)

Subject

General Medicine

Reference22 articles.

1. A desinfecção de endoscópios com ácido peracético por dez minutos é efetiva?;Carrara D;Rev SOBECC.,2013

2. Avaliação microbiológica in vitro da desinfecção de instrumentos na prática ortodôntica;Tengan C;Rev Cienc Salud,2016

3. Esterilização de instrumentais e desinfecção de artigos odontológicos com ácido peracético: revisão de literatura;Dourado R;J Biodentistry Biomater.,2011

4. Controle de infecção e a prática odontológica em tempos de AIDS: manual de condutas;Golegã AAC,2000

5. Infecção cruzada em odontologia: riscos e diretrizes;Zenkner CL;Rev End Pes Ens Online.,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3