Affiliation:
1. Universidade Federal de Pernambuco, Brazil
Abstract
Introduction Pain represents a frequent phenomenon among the general population with great socio-economic impact. TENS is one of the most common forms of electroanalgesia. However, totally effective stimulation parameters remain uncertain. Thus, this study aims to assess the effects of 4 Hz, 10 Hz and 100 Hz TENS applied to the LU7 (Lieque) acupoint on cold-induced pain in young healthy subjects. Methods 100 volunteers, divided into five groups (three TENS groups, one electrode group and one placebo group), completed six experimental cycles. Each cycle comprised three phases: pretreatment, treatment and post-treatment. In each cycle, pain was induced by immersion of the hand into ice water and the pain threshold latency was measured. For the analysis of results, we used the one-way ANOVA test, followed by the Student-Newman-Keuls post hoc test. The level of significance was p < 0.05. Results The 4 Hz TENS group the pain showed elevation of the pain threshold during the treatment phase, when compared to pretreatment (p < 0.05). This elevation was maintained in the post-treatment phase. The other groups showed no changes in the pain threshold. Conclusion 4 Hz TENS applied with 1x1 cm electrodes to LU7 acupoint increases hypothermia-induced pain threshold latency in young healthy subjects.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献