NON-RADIOMETRIC IMMUNOASSAYS [FLUOROIMMUNOASSAY (FIA) AND FLUOROMETRIC ENZYME IMMUNOASSAY (FEIA)] WITH RADIOIMMUNOASSAY (RIA) FOR EVALUATION OF ADRENAL FUNCTION IN NORMAL AND HYPERCORTISOLEMIC DOGS

Author:

Jericó Márcia Marques1,Mendonça Berenice Bilharino de2,Otsuka Mary3,Maganin Jr Aristides4,Larsson Carlos Eduardo3

Affiliation:

1. Universidade de Santo Amaro; Universidade Bandeirantes

2. Universidade de São Paulo

3. USP

4. Kennel of the Policia Militar do Estado de São Paulo

Abstract

Non-radiometric immunoassays offer many advantages over radiometric assays, such as higher stability of kit compounds and absence of potential hazardous effects for users and environment. The comparison of cortisol measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in adrenal function evaluation of normal (n=50) and hypercortisolemic dogs (n=12) was proposed. Serum concentrations of cortisol were measured in basal conditions and 8 hours after dexamethasone (DEX) suppression (0.01mg/kg/IV). All our reference values were based on the 5th and 95th percentile. The values for basal cortisol of healthy dogs were 0.20 to 2.35mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for FIA, 0.30 to 5.39mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for FEIA, and 0.65 to 4.64mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for RIA. After DEX suppression the values were <0.87mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif">, <0.30mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> and < 0.80mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for FIA, FEIA and RIA, respectively. In hypercortisolemic dogs, the values of cortisol (mean ± SD) in basal and post-DEX conditions were 2.71 + 0.41mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> and 1.73 + 1.15mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for FIA, 7.05 + 2.85mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> and 4.93 + 2.26mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for FEIA, and 4.80 + 1.43mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> and 3.52 + 1.08mug/d<img SRC="http:/img/fbpe/cr/v32n2/a12img01.gif"> for RIA. Statistically significant differences (p<0.05) between the normal and the hypercortisolemic groups (Kruskal-Wallis test) were observed in the three methods, and between basal and post-DEX values (Wilcoxon test) using RIA and FEIA methods but not with FIA. Cortisol determinations by FEIA and RIA methods at DEX suppression test showed 100% of sensitivity and specificity for the diagnosis of hyperadrenocorticism in dogs. The results demonstrate that serum cortisol concentrations measurements by FEIA is a suitable alternative to the traditional RIA method for adrenal function evaluation in dogs.

Publisher

FapUNIFESP (SciELO)

Subject

General Veterinary,Agronomy and Crop Science,Animal Science and Zoology

Reference12 articles.

1. Hormonal assay methodology present and future prospects;ALBERTSON B.D.;Clin Obstet Gynecol,1990

2. Canine and feline endocrinology and reproduction;FELDMAN E.C.,1996

3. Radial partition immunoassay;GIEGEL J.L.;Clin Chem,1982

4. Diagnosis of canine hyperadrenocorticism;GUPTILL L.;Vet Clin North Am Small Anim Pract,1997

5. Determination of canine prolactin by use of a commercial heterologous enzymeimmunoassay kit;HOIER R.;J Vet Med,1996

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3