Evaluating the aqueous portion of tears in shih tzu dogs: comparing Schirmer tear test 1 with tear meniscus height

Author:

Silva P.H.S.1ORCID,Cruz L.K.S.2,Ferreira B.M.2ORCID,Falcão M.S.A.2ORCID,Barreto-Vianna A.R.C.3ORCID,Lima E.M.M.1ORCID

Affiliation:

1. Universidade de Brasília, Brasil

2. , Brasil

3. Universidade Federal do Paraná, Brasil

Abstract

ABSTRACT The aqueous portion of the tear film has been characterized as an essential structure for ocular surface health. Among various assessment tests, some measure the aqueous portion, such as Schirmer Tear Test 1, Meniscometry using a strip, and the test to determine Tear Meniscus Height (TMH). Conversely, few studies have specifically evaluated tear meniscus height, especially those utilizing ocular surface analyzers. Therefore, the aim of this study was to comparatively evaluate the results obtained from employing Tear Meniscus Height (TMH) using an Ocular Surface Analyzer and Schirmer Tear Test 1 (STT-1) in Shih Tzu dogs. To achieve this, the eyes of 18 brachycephalic Shih Tzu dogs of both sexes and varying ages were assessed and compared. The results revealed that the TMH for the right eye was 0.59±0.29mm, and for the left eye was 0.88±0.27mm; p=0.0135. For STT-1, it was found that the right eye had a value of 19.06±4.87mm/min, and the left eye had a value of 23.11±4.80mm/min; p=0.0238. Furthermore, the Pearson correlation test applied between TMH and STT-1 yielded the following results for the right eye (r=0.601; p=0.008) and the left eye (r=-0.032; p=0.8979). The TMH shows potential as an alternative to STT-1 for evaluating the aqueous component of tear film in a similar manner. However, further research is warranted, particularly for establishing reference values for TMH and conducting a comprehensive comparison between STT-1 and TMH. This research is especially important for gathering information that can contribute to the understanding of ophthalmic and systemic conditions that directly influence the physiological composition of tears. Critical for establishing the values obtained when measuring the canine lacrimal meniscus using different techniques is the consideration of associated functional factors.

Publisher

FapUNIFESP (SciELO)

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3