Accuracy evaluation of two portable blood glucose meters in feline patients using whole blood samples

Author:

Moresco Maurício Bianchini1ORCID,Matesco Viviana Cauduro2ORCID,Martins Francisco Sávio de Moura1ORCID,Carvalho Guilherme Luiz Carvalho de1ORCID,Schaefer Gabriela da Cruz1ORCID,Nunes Nilson Júnior da Silva3ORCID,Valle Stella de Faria4ORCID,Pöppl Álan Gomes3ORCID

Affiliation:

1. Universidade Federal do Rio Grande do Sul (UFRGS), Brazil

2. Centro Universitário Ritter dos Reis (UniRitter), Brazil

3. Universidade Federal do Rio Grande do Sul (UFRGS), Brazil; Universidade Federal do Rio Grande do Sul (UFRGS), Brazil

4. Universidade Federal do Rio Grande do Sul (UFRGS), Brazil; Universidade Federal do Rio Grande do Sul (UFRGS), Brazil; Universidade Federal do Rio Grande do Sul (UFRGS), Brazil

Abstract

ABSTRACT: Using portable blood glucose meters (PBGMs) to measure blood glucose (BG) concentration is a common procedure in veterinary practice. Our objective was to evaluate the analytical and clinical accuracy of a human PBGM (Accu-Chek Performa®), (AC) and a veterinary PBGM (GlucoCalea®), (GC) in feline patients. Central venous blood samples were collected from 48 cats at a Brazilian Veterinary teaching hospital. Two devices from each model were used and compared to a reference method (RM). Analytical accuracy was assessed according to ISO 15197:2013 requirements for human PBGMs. Data were compared using Wilcoxon’s nonparametric test and represented by Bland-Altman plots. Hematocrit’s effect on BG measurements was evaluated by the Spearman correlation coefficient. Clinical accuracy was determined using error grid analysis (EGA). Values of BG were significantly higher in all PBGMs compared to the RM. Although ISO’s analytical accuracy requirements could not be met by any of the devices, AC meters were more accurate than GC meters. All AC measurements - but not GC ones - were within zones A and B of the EGA, meeting ISO requirements for clinical accuracy. Significant hematocrit interference was observed in all devices. Therefore, AC showed greater accuracy compared to GC using feline whole blood samples.

Publisher

FapUNIFESP (SciELO)

Subject

General Veterinary,Agronomy and Crop Science,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3