Abstract

ABSTRACT: Proper monitoring of cardiac index (CI) in critically ill patients requires accurate and minimally invasive methods. The aim of this study was to compare the CI values obtained by thermodilution or echocardiography using different methods in dogs in different hemodynamic states. Nine dogs weighing 19.6±1.3kg were anesthetized with isoflurane at 1.4V% (Baseline) and subjected to mechanical ventilation (MV),a hypodynamic state (Hypo) with isoflurane at 3.5V% and hyperdynamic state (hyper) with dobutamine infusion at 5μgkg-1min-1. CI analysis was performed by thermodilution (TD) and using the modified Simpson's method, aortic velocity-time integral (A-VTI) method and pulmonary VTI (P-VTI) method. We performed Pearson's correlation and Bland-Altman analysis. The CI values (Lm-2min-1) of the animals in the Baseline, MV, Hypo and Hyper states were 4.3±1, 3.6±0.7, 2.9±0.66 and 6.1±2, for TD; 2.8±0.7, 2.4±0.3, 1.7±0.7 and 4.4±1.2, for Simpson's method; 3.4±0.9, 3.1±0.7, 2.6±3.4, 6.1±1.8 for A-VTI; and 3.6±0.8, 3.6±0.8, 2.7±0.6 and 6.2±1.5, for P-VTI. The CI values using Simpson's method were lower than those obtained by TD in all states, and it was observed a significant correlation in the Hypo (r=0.89) and Hyper (r=0.76) groups. In addition,the percent error in the Hypo group using Simpson's method was 26% relative to TD, which allowed for the identification of the different hemodynamic states. With respect to the other methods and states, there was no agreement or correlation between the methods and TD. We concluded that none of the tested echocardiography methods exhibited acceptable agreement with thermodilution at different hemodynamic states.

Publisher

FapUNIFESP (SciELO)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3