Abstract
This study evaluated the influence of bleaching protocols on intrapulpal temperature and fracture strength of the bleached teeth. Ninety maxillary incisors were assigned to 9 groups (n=10): G1: 35% carbamide peroxide (35% CP), G2: 38% hydrogen peroxide (38% HP), G3: halogen light, G4: LED-laser, G5: 35% CP + halogen light, G6: 38% HP + halogen light, G7: 35% CP + LED-laser, G8: 38% HP + LED-laser, and G9: no treatment (control). Pulp space was widened, a thermocouple was introduced through the apex up to the pulp chamber and the temperature was recorded (°C). The fracture strength (kN) was determined using an Instron machine. Data were analyzed by ANOVA and Tukey's test (p<0.05). The halogen light alone (1.10 ± 0.24) (G3) and associated with 38% HP (1.15 ± 0.30) (G6) produced the highest temperature increase, statistically different (p<0.05) from the other groups. G1 (0.15 ± 0.06) and G6 (0.19 ± 0.07) produced the lowest values, statistically different (p<0.05) from G5 (0.65 ± 0.49). The bleaching protocols increased the temperature, but no increment exceeded the critical value of 5.6°C. Neither 35% CP nor 38% HP or the light sources alone altered the fracture strength of the teeth.