Evaluation of screw loosening on new abutment screws and after successive tightening

Author:

Barbosa Gustavo Seabra1,Silva-Neto João Paulo da2,Simamoto-Júnior Paulo Cezar2,Neves Flávio Domingues das2,Mattos Maria da Gloria Chiarello de3,Ribeiro Ricardo Faria3

Affiliation:

1. Federal University of Rio Grande do Norte, Brazil

2. Federal University of Uberlândia, Brazil

3. University of São Paulo, Brazil

Abstract

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.

Publisher

FapUNIFESP (SciELO)

Subject

General Dentistry

Reference20 articles.

1. Implant prosthodontic and restorative complications;Wolfinger GJ;Int J Oral Maxillofac Implants,2003

2. Clinical complications with implants and implant prostheses;Goodacre CJ;J Prosthet Dent,2003

3. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies;Byrne D;J Prosthodont,2006

4. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants;Patterson EA;Int J Oral Maxillofac Implants,1992

5. Finite element analysis to determine implant preload;Lang LA;J Prosthet Dent,2003

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3