External Hexagon Deformation in Implants Subjected to Internal Torque

Author:

Magalhães Denildo1,Naves Marina Melo1,Menezes Helder Henrique Machado2,Bataglion César3,Magalhães Guilherme Carminati1,Santos Filho Paulo César Freitas1

Affiliation:

1. Federal University of Uberlândia, Brazil

2. Dental School, Brazil

3. São Paulo University, Brazil

Abstract

<p>Failures may occur in the connections of dental implants, especially in external hexagon (EH). Due to the deformations in this portion of implants, this study aimed to evaluate the levels of deformation of EH connections subjected to internal toque. Two types of implants were used: N group and S group. Torques of 0, 32, 45, 60 and 80 Ncm were applied to the N group, and torques of 0, 30, 40, 60 and infinite Ncm were applied to the S group implants. The internal distance (ID), internal area (IA) and external area (EA) of the EH were obtained from digital pictures, which were analyzed by a specific software. Statistical analysis was performed by the Scott-Knott test. The results showed that the higher the torque applied, the greater were the changes in the evaluated dimensions in both groups. In the S group, torque levels equal or greater than 40 Ncm and 30 Ncm caused greater deformation of EA and IA respectively, while in the N group, torque levels equal or greater than 60 Ncm and 32 Ncm caused greater deformation of EA and IA respectively. Levels of deformation were greater in the S group as compared with the N group. These findings suggest that the IA, EA and ID of the EH may be affected by different internal torque levels.</p>

Publisher

FapUNIFESP (SciELO)

Subject

General Dentistry

Reference20 articles.

1. The effect of thread pattern upon implant osseointegration;Abuhussein H;Clin Oral Implants Res,2010

2. Effect of microthread presence and restoration design (screw versus cemented) in dental implant reliability and failure modes;Almeida EO;Clin Oral Implants Res,2013

3. Effect of implant-abutment connection design on reliability of crowns: regular vs. horizontal mismatched platform;Freitas Júnior AC;Clin Oral Implants Res,2012

4. An evaluation of fit in osseointegrated implant components using torque/turn analysis;Wicks RA;J Prosthodont,1994

5. Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period;Branemark PI;Scand J. Plast Reconstr Surg,1977