Dosimetry in CBCT with Different Protocols: Emphasis on Small FOVs Including Exams for TMJ

Author:

Nascimento Helena Aguiar Ribeiro1,Andrade Marcos Ely Almeida2,Frazão Marco Antonio Gomes3,Nascimento Eduarda Helena Leandro1,Ramos-Perez Flavia Maria Moraes2,Freitas Deborah Queiroz1

Affiliation:

1. Universidade de Campinas, Brazil

2. Universidade Federal de Pernambuco, Brazil

3. Faculdade de Odntologia de Recife, Brazil

Abstract

Abstract This study aimed to estimate the absorbed dose in cone beam computed tomography (CBCT) exams according to different exposure parameters and size and position of the field of view (FOV). In addition was compared the absorbed dose of two smaller FOV scans with that of a larger FOV scan for evaluation of temporomandibular joint (TMJ), as it is a bilateral structure. CBCT scans were obtained on OP300 Maxio unit varying scanning mode (standard, high and endo) as well as size (5x5, 6x8 and 8x15 cm) and positioning of FOV. With a small FOV, different areas were scanned (maxilla or mandible, anterior or posterior and TMJ). Absorbed doses were determined using thermoluminescent dosimeters on the skin surface of sensitive organs of an anthropomorphic phantom. Endo mode showed the highest dose, followed by the high and standard modes in all FOV positions. With small FOV, doses were higher in the posterior region, especially in the mandible. Dose reduction occurred when small FOVs were used, but it was not proportional to FOV size reduction. For TMJ, the dose in a single acquisition with large FOV was greater than two acquisitions with small FOV, but lower than two acquisitions with medium FOV (6x8 cm). In conclusion, scanning mode, size and FOV position have great influence on the absorbed dose. Small FOV decreases the dose, but there is no linear relation between FOV size and dose. For bilateral exams of TMJ, double acquisition with small FOVs produces decrease in absorbed dose relative to a large FOV.

Publisher

FapUNIFESP (SciELO)

Subject

General Dentistry

Reference22 articles.

1. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results;Mozzo P;Eur Radiol,1998

2. Development of a compact computed tomographic apparatus for dental use;Arai Y;Dentomaxillofac Radiol.,1999

3. Cone beam CT for dental and maxillofacial imaging: dose matters;Pauwels R;Radiat Prot Dosimetry,2015

4. Dosimetric evaluation of dental implant planning examinations with cone-beam computed tomography;Andrade ME;Radiat Prot Dosimetry,2014

5. Safety and efficacy of a new and emerging dental X-ray modality;SEDENTEXCT guidelines,2012