New approaches are needed to quickly indicate possible contamination of UHT milk, among them the technique of ATP-Bioluminescence. Therefore, the aim of this study was to compare the results of culture methods with the results of ATP-Bioluminescence technique of 102 UHT whole milk samples incubated at 48, 72, and 168 hours. UHT milk samples were analyzed for the presence of mesophilic and psychrotrophic aerobic microorganisms using Plate Count Agar (PCA), Brain-Heart Infusion (BHI) media and PetrifilmTM Aerobic Count (AC) plates. The ATP-Bioluminescence technique was applied through the Microbial Luminescent Screening (MLS) system. Significant correlations were found between counts of aerobic mesophilic microorganisms on PCA, PetrifilmTM AC, BHI and results of ATP bioluminescence technique (P≤0.05). The ATP-Bioluminescence technique had higher correlation with counting method in PCA than BHI media. At lower pass/fail limits of Relative Light Units (60, 50, 45 and 40 RLU), the number of samples identified as positive increased and statistically agreed with aerobic mesophilic microorganism counts (P>0.05). For the dairy industry, the ATP-Bioluminescence technique may become an important tool that assists the official methods to quickly monitor the microbiological quality of UHT milk though this will likely require a threshold below 150 RLU.

Publisher

FapUNIFESP (SciELO)

Subject

General Veterinary

Reference29 articles.

1. Microbial Luminescence System (MLS)

2. 3M(tm) Petrifilm(tm) Aerobic Count Plates,2003

3. Bacterial bioluminescence: applications in food microbiology;BAKER J.M.;J. of Food Protec.,1992

4. Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method;BELL C.;Internat. Dairy J.,1996

5. Portaria Nº 370 de 4 de setembro de 1997. Regulamento Técnico de Identidade e Qualidade do leite UAT (UHT);Diário Oficial da União,1997

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Beverage Deterioration Monitoring Based on Surface Tension Dynamics and Absorption Spectrum Analysis;IEEE Transactions on Mobile Computing;2023

2. Quantifying milk proteins using infrared photodetection for portable equipment;Journal of Food Engineering;2021-11

3. Lili;Proceedings of the 27th Annual International Conference on Mobile Computing and Networking;2021-10-19

4. Rapid methods and sensors for milk quality monitoring and spoilage detection;Biosensors and Bioelectronics;2019-09

5. A rapid method on identifying disqualified raw goat's milk based on total bacterial count by using dielectric spectra;Journal of Food Engineering;2018-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3