EVALUATION OF METHODS IN DETECTING VANCOMYCIN MIC AMONG MRSA ISOLATES AND THE CHANGES IN ACCURACY RELATED TO DIFFERENT MIC VALUES

Author:

Rossatto Fernanda Cristina Possamai1,Proença Letícia Auler1,Becker Ana Paula2,Silveira Alessandro Conrado de Oliveira1,Caierão Juliana1,D'azevedo Pedro Alves1

Affiliation:

1. Federal University of Health Science of Porto Alegre, Brazil

2. Federal University of Health Science of Porto Alegre, Brazil; Mãe de Deus Hospital, Brazil

Abstract

INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.

Publisher

FapUNIFESP (SciELO)

Subject

Infectious Diseases,General Medicine

Reference22 articles.

1. Novel screening agar for detection of vancomycin-nonsusceptible Staphylococcus aureus;Burnham CD;J Clin Microbiol,2010

2. Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos;Campana EH;J Bras Patol Med Lab,2011

3. Interim guidelines for prevention and control of staphylococcal infection associated with reduced suscetibility to vancomycin;MMWR Morb Mortal Wkly Rep,1997

4. Staphylococcus aureus resistent to vancomycin - United States, 2002;MMWR Morb Mortal Wkly Rep,2002

5. Performance Standards for Antimicrobial Susceptibility Testing: Seventeenth Informational Supplement;CLSI,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3