Agreement and reproducibility of a portable electrical impedance myography device for body fat percentage estimation in normal weight men and women

Author:

Ribeiro Josiel Gomes1ORCID,Rossato Mateus1ORCID,Orssatto Lucas Bet da Rosa2ORCID,Picanço Luhan Ammy Andrade1ORCID,Silva Diego Augusto Santos3ORCID,Bezerra Ewertton de Souza1ORCID

Affiliation:

1. Universidade Federal do Amazonas, Brasil

2. Queensland University of Technology, Australia

3. Universidade Federal de Santa Catarina, Brasil

Abstract

Abstract The aim of this study was to investigate the agreement and reproducibility of a portable electrical impedance myography device (EIM - SKULPT®) for body fat percentage (BF%) estimation in young adults. Sixty young adults volunteered for the study (women, n=30, 25.0±7.7 years; 21.5±1.9 kg/m2; and men, n=30, 21.6±6.3 years; 22.5±1.8 kg/m2). Participants underwent air displacement plethysmography (ADP) and EIM measurements for agreement analysis. EIM was performed three times on the same day for the within-day reproducibility analysis. Seven days later, 37 participants repeated the EIM measurements for the between-days reproducibility analysis. Comparisons of EIM and ADP methods, and EIM repeated measurements were performed with the paired T-test or one-way ANOVA repeated measures, the Bland-Altman plot, and simple linear regressions. BF% was higher (p<0.05) when estimated by EIM (19.91 ± 5.70 for men, and 30.77 ± 5.89 for women) compared to ADP (15.28 ± 5.66 for men, and 27.31 ± 5.98 for women). The Bland-Altman analysis presented a bias of 4.4% (95%CI=-3.4–12.2) and linear regression presented an R2=0.78. For between-days reproducibility, EIM means did not differ (25.33±7.69 and 24.94±8.30, p=0.890). Thus, while the EIM device exhibited high reproducibility of BF% estimates, caution should be exercised when comparing the results with other techniques for measuring BF%. The EIM device overestimated BF% compared to ADP. However, the EIM measurements presented very good within-day and between-days reproducibility and, thus, the EIM device can be used for longitudinal monitoring of BF%.

Publisher

FapUNIFESP (SciELO)

Subject

Physiology (medical),Physiology

Reference26 articles.

1. Obesity and overweight,2018

2. Obesity and cancer risk: evidence, mechanisms, and recommendations;Vucenik I;Ann N Y Acad Sci,2012

3. Medicine expenses and obesity in Brazil: an analysis based on the household budget survey;Canella DS;BMC Public Health,2015

4. Reproducibility and validity of A-mode ultrasound for body composition measurement and classification in overweight and obese men and women;Smith-Ryan AE;PLoS One,2014

5. Measuring body composition;Wells JCK;Arch Dis Child,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3