Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury

Author:

Valiatti Jorge Luís dos Santos1,Amaral José Luiz Gomes do2

Affiliation:

1. Faculdade de Medicina de Catanduva

2. Universidade Federal de São Paulo, Brazil

Abstract

CONTEXT: Thermodilution, which is considered to be a standard technique for measuring the cardiac output in critically ill patients, is not free from relevant risks. There is a need to find alternative, noninvasive, automatic, simple and accurate methods for monitoring cardiac output at the bedside. OBJECTIVE: To compare cardiac output measurements by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury at two levels of severity (lung injury score, LIS: below 2.5, group A; and above 2.5, group B). TYPE OF STUDY: Comparative, prospective and controlled study. SETTING: Intensive Care Units of two university hospitals. METHODS: Cardiac output was measured by thermodilution and partial carbon dioxide rebreathing. Twenty patients with acute lung failure (PaO2/FiO2 < 300) who were under mechanical ventilation and from whom 294 measurements were taken: 164 measurements in group A (n = 11) and 130 in group B (n = 9), ranging from 14 to 15 determinations per patient. RESULTS: There was a poor positive correlation between the methods studied for the patients from groups A (r = 0.52, p < 0.001) and B (r = 0.47, p < 0.001). The application of the Bland-Altman test made it possible to expose the lack of agreement between the methods (group A: -0.9 ± 2.71 l/min; 95% CI = -1.14 to -0.48; and group B: -1.75 ± 2.05 l/min; 95% CI = -2.11 to -1.4). The comparison of the results (Student t and Mann-Whitney tests) within each group and between the groups showed significant difference (p = 0.000, p < 0.05). DISCUSSION: Errors in estimating CaCO2 (arterial CO2 content) from ETCO2 (end-tidal CO2) and situations of hyperdynamic circulation associated with dead space and/or increased shunt possibly explain our results. CONCLUSION: Under the conditions of this study, the results obtained allow us to conclude that, in patients with acute lung injury, the cardiac output determined by partial rebreathing of CO2 differs from the measurements obtained by thermodilution. This difference becomes greater, the more critical the lung injury is.

Publisher

FapUNIFESP (SciELO)

Subject

General Medicine

Reference40 articles.

1. A new technique for measurement of cardiac output by thermodilution in man;Ganz W;Am J Cardiol,1971

2. Cardiac output measurement by thermal dilution: reproducibility and comparison with the dye-dilution technique;Sorensen MB;Ann Surg,1976

3. Reliability of the thermodilution method in the determination of cardiac output in clinical practice;Stetz CW;Am Rev Respir Dis,1982

4. Cardiac output determination: thermodilution versus a new computerized Fick method;Carpenter JP;Crit Care Med,1985

5. Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU;Steingrub JS;Chest,1991

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3