Quantitative evaluation of microleakage in class V cavities using one-bottle and self-etching adhesive systems

Author:

França Fabiana Mantovani Gomes1,Aguiar Flávio Henrique Baggio1,Santos Alex José Souza dos1,Lovadino José Roberto1

Affiliation:

1. State University of Campinas

Abstract

The aim of this in vitro study was to evaluate quantitatively the microleakage in class V cavities restored with one-bottle and self-etching adhesive systems with and without previous acid etching. Two one-bottle adhesive systems (Single Bond and Prime & Bond 2.1) and one self-etching adhesive system (Clearfil Mega Bond) were used in this study. One hundred and twenty sound human premolar teeth were randomly divided into 6 groups, and 20 class V restorations were prepared in the root dentin to test each bonding system. Each bonding system was used with and without acid etching. Specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with an absorbance spectrophotometer test in order to quantify the infiltrated dye. Results were statistically evaluated by ANOVA and Tukey-Kramer test. No statistically significant differences were found among the adhesive systems when no etching agent was used. However, the Single Bond adhesive system showed statistically significant lower microleakage means than Clearfil Mega Bond and Prime & Bond 2.1 when 37% phosphoric acid was used. Single Bond and Clearfil Mega Bond adhesive systems presented similar behavior when the manufacturers' instructions were followed.

Publisher

FapUNIFESP (SciELO)

Subject

Electrical and Electronic Engineering,Atomic and Molecular Physics, and Optics

Reference30 articles.

1. Bond strength of composite to enamel and dentin using Prime & Bond 2. 1;Barkmeier WW;Oper Dent,1999

2. Bond strengths and SEM evaluation of Clearfil Liner Bond 2;Barkmeier WW;Am J Dent,1995

3. Microleakage of multi-step and simplified-step bonding systems;Castelnuovo J;Am J Dent,1996

4. Influence of criteria on the results of in vitro evaluation of microleakage;Déjou J;Dent Mater,1996

5. Volumetric assessment of apical leakage utilizing a spectrophotometric, dye-recovery method;Douglas WH;J Dent Res,1981