Affiliation:
1. Universidade de São Paulo, Brasil
Abstract
abstract: This work deals with the evaluation of the design criteria and security check (Ultimate Limit State - ULS) of the American (ACI-440.2R, 2017) and European (FIB Model Code, 2010) standards of reinforced concrete structures strengthened with Carbon Fiber Reinforced Polymers (CFRP), by the technique of Externally Bonded Reinforcement (EBR). It is intended to evaluate if, for a given database of 64 experimental tests of beams and slabs, the obtained results respect the safety conditions according to the mentioned standards, to increase the efficiency of this reinforcement technique and to lead to the establishment of regulatory design criteria in Brazil. Results show a conservative match among experimental and theoretical values calculated according to the two guidelines and it is concluded that a future regulation in Brazil on this subject should be based on the FIB Model Code.
Reference47 articles.
1. Performances, challenges and opportunities in strengthening reinforced concrete structures by using FRPs: a state-of-the-art review;Siddika A.;J. Eng. Fail. Anal.,2020
2. Verifications of design equations of beams externally strengthened with FRP composites;Toutanji H.;J. Compos. Constr.,2006
3. External reinforcement of concrete beams using fiber reinforced plastics;Ritchie P.;ACI Struct. J.,1991
4. Strengthening of initially loaded reinforced concrete beams using FRP plates;Sharif A.;ACI Struct. J.,1994