Abstract
Experimental determination of microsprinkler droplets is difficult and time-consuming. This determination, however, could be achieved using ballistic models. The present study aimed to compare simulated and measured values of microsprinkler droplet diameters. Experimental measurements were made using the flour method, and simulations using a ballistic model adopted by the SIRIAS computational software. Drop diameters quantified in the experiment varied between 0.30 mm and 1.30 mm, while the simulated between 0.28 mm and 1.06 mm. The greatest differences between simulated and measured values were registered at the highest radial distance from the emitter. The model presented a performance classified as excellent for simulating microsprinkler drop distribution.
Subject
Agronomy and Crop Science,Animal Science and Zoology
Reference20 articles.
1. Sprinkler droplet size distribution estimation from single leg test data;BERNUTH R.D. von;Transactions of the ASAE,1984
2. Avaliação do desempenho de diferentes métodos de estimativa da evapotranspiração potencial no Estado de São Paulo, Brasil;CAMARGO A.P. de;Revista Brasileira de Agrometeorologia,1997
3. SIRIAS: a simulation model for sprinkler irrigation. I. Description of the model;CARRIÓN P.;Irrigation Science,2001