Effect of light curing tip distance and resin shade on microhardness of a hybrid resin composite

Author:

Aguiar Flávio Henrique Baggio1,Lazzari Carolina Rodrigues1,Lima Débora Alves Nunes Leite1,Ambrosano Glaucia Maria Bovi1,Lovadino José Roberto1

Affiliation:

1. Campinas State University

Abstract

Resin composite shades and resin composite polymerization performed with a distanced light tip are factors that can affect polymerization effectiveness. Thisin vitro study aimed to evaluate the influence of curing tip distance and resin shade on the microhardness of a hybrid resin composite (Z250 - 3M ESPE). Forty-five resin composite specimens were randomly prepared and divided into nine experimental groups (n = 5): three curing tip distances (2 mm, 4 mm, and 8 mm) and three resin shades (A1, A3.5, and C2). All samples were polymerized with a continuous output at 550 mW/cm². After 24 hours, Knoop microhardness measurements were obtained on the top and bottom surfaces of the sample, with a load of 25 grams for 10 seconds. Five indentations were performed on each surface of each sample. Results showed that bottom surface samples light-cured at 2 mm and 4 mm presented significantly higher hardness values than samples light-cured at 8 mm. The resin shade A1 presented higher hardness values and was statistically different from C2. The resin shade A3.5 did not present statistical differences from A1 and C2. For the top surface, there were no statistical differences among the curing tip distances. For all experimental conditions, the top surface showed higher hardness values than the bottom surface. It was concluded that light curing tip distance and resin shade are important factors to be considered for obtaining adequate polymerization.

Publisher

FapUNIFESP (SciELO)

Subject

Electrical and Electronic Engineering,Atomic and Molecular Physics, and Optics

Reference19 articles.

1. Some factors influencing the depth of cure of visible light-activated resin composite;Atmadja G;Aust Dent J,1990

2. The cause of post-restorative sensitivity and its prevention;Brännström M;J Endod,1986

3. Influence of curing tip distance on resin composite Knoop hardness number, using three different light curing units;Caldas DBM;Oper Dent,2003

4. Influence of curing tip distance on composite Knoop hardness values;Correr Sobrinho L;Braz Dent J,2000

5. Fourier transform infrared analysis of degree of polymerization of unfilled resins: methods comparison;Ferracane JL;J Dent Res,1984

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3