What patient positioning in chest X-ray is still acceptable? – An empirical study on thresholding quality metrics

Author:

von Berg Jens1ORCID,Hergaarden Kenneth F. M.2,Englmaier Max3,Pfeiffer Daniela34,Wieberneit Nataly5,Krönke-Hille Sven1,Harder Tim1,Gooßen André1,Bystrov Daniel1,Brueck Matthias1,Young Stewart1,Lamb Hildo J.2

Affiliation:

1. Philips Innovative Technologies, Röntgenstr 24–26, 22335 Hamburg, Germany

2. Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands

3. Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum Rechts der Isar, Technical University of Munich, Ismaningerstr 22, 81675 Munich, Germany

4. Institute for Advanced Study, Technical University of Munich, Lichtenbergstrase 2a, 85748 Garching bei München, Germany

5. Philips Medical Systems DMC, Röntgenstr 24–26, 22335 Hamburg, Germany

Abstract

AbstractBackground and AimIssues in patient positioning during chest X-ray (CXR) acquisition impair diagnostic quality and potentially increase radiation dose. Automated quality assessment was proposed to address this. Our objective is to determine thresholds on some quality control metrics following international guidelines, that represent expert knowledge and can be applied in a comprehensible and explainable AI approach for such an automatic quality assessment.Materials and MethodsAn AI-method estimating collimation distance to the ribcage, balancing between both clavicle heads, and number of ribs above the diaphragm as metrics for collimation, rotation, and inhalation quality was applied on 64,315 posteroanterior CXR images from a public dataset (ChestX-ray8). From this set 920 CXR images were sampled and manually annotated to gain additional trusted reference metrics. Seven readers from different institutions then classified the acquisition quality of these images independently into okay, inadequate, or unacceptable following the criteria of international guidelines. Optimal thresholds on the metrics were determined to reproduce these classes using the metrics only.ResultsA fair to moderate agreement between the experts was found. When disregarding all inadequate rates a classification on the metrics was able to separate okay rated cases from unacceptable cases for collimation (AUC 0.97), rotation (AUC = 0.93) and inhalation (AUC = 0.97).ConclusionSuitable thresholds were determined to reproduce expert opinions in the assessment of the most important quality criteria in CXR acquisition. These thresholds were finally applied on the AI-method's estimates to automatically classify image acquisition quality comprehensibly and according to the guidelines.

Publisher

Akademiai Kiado Zrt.

Reference17 articles.

1. Digital radiography reject analysis: data collection methodology, results, and recommendations from an in-depth investigation at two hospitals;Foos DH,2009

2. ACR-SPR practice parameter for the performance of chest radiography Res. 56-2011, amended 2014 (Res. 39);American College of Radiology (ACR)

3. European guidelines on quality criteria for diagnostic radiographic images;Carmichael JHE,1996

4. Digital chest radiography image quality assessment with dose reduction;Grewal RK,2012

5. Clinical audit of image quality in radiology using visual grading characteristics analysis;Tesselaar E,2016