Post-hoc motion correction for coronary computed tomography angiography without additional radiation dose - Improved image quality and interpretability for “free”

Author:

Degtiarova Ganna1,Mikulicic Fran1,Vontobel Jan1,Garefa Chrysoula1,Keller Lukas S.1,Boehm Reto1,Ciancone Domenico1,Gebhard Catherine1,Pazhenkottil Aju P.1,Kaufmann Philipp A.1,Buechel Ronny R.1ORCID

Affiliation:

1. Department of Nuclear Medicine, Cardiac Imaging, University and University Hospital Zurich, Zurich, Switzerland

Abstract

AbstractObjectiveTo evaluate the impact of a motion-correction (MC) algorithm, applicable post-hoc and not dependent on extended padding, on the image quality and interpretability of coronary computed tomography angiography (CCTA).MethodsNinety consecutive patients undergoing CCTA on a latest-generation 256-slice CT device were prospectively included. CCTA was performed with prospective electrocardiogram-triggering and the shortest possible acquisition window (without padding) at 75% of the R-R-interval. All datasets were reconstructed without and with MC of the coronaries. The latter exploits the minimal padding inherent in cardiac CT scans with this device due to data acquisition also during the short time interval needed for the tube to reach target currents and voltage (“free” multiphase). Two blinded readers independently assessed image quality on a 4-point Likert scale for all segments.ResultsA total of 1,030 coronary segments were evaluated. Application of MC both with automatic and manual coronary centerline tracking resulted in a significant improvement in image quality as compared to the standard reconstruction without MC (mean Likert score 3.67 [3.50;3.81] vs 3.58 [3.40;3.73], P = 0.005, and 3.7 [3.55;3.82] vs 3.58 [3.40;3.73], P < 0.001, respectively). Furthermore, MC significantly reduced the proportion of non-evaluable segments and patients with at least one non-evaluable coronary segment from 2% to as low as 0.3%, and from 14% to as low as 3%. Reduction of motion artifacts was predominantly observed in the right coronary artery.ConclusionsA post-hoc device-specific MC algorithm improves image quality and interpretability of prospectively electrocardiogram-triggered CCTA and reduces the proportion of non-evaluable scans without any additional radiation dose exposure.

Publisher

Akademiai Kiado Zrt.

Subject

Radiology, Nuclear Medicine and imaging,Medicine (miscellaneous),Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3