A dóziscsökkentés lehetőségei CT-képalkotás során az iteratív képrekonstrukció alkalmazásával

Author:

Bajzik Gábor1,Tóth Anett1,Donkó Tamás2,Kovács Péter134,Sipos Dávid134,Pandur Attila András4,Moizs Mariann1,Hadjiev Janaki1,Repa Imre14,Kovács Árpád134

Affiliation:

1. Dr. Baka József Diagnosztikai, Onkoradiológiai, Kutatási és Oktatási Központ, Somogy Megyei Kaposi Mór Oktató Kórház Kaposvár

2. Medicopus Nonprofit Kft. Kaposvár

3. Képalkotó Diagnosztikai Tanszék, Pécsi Tudományegyetem, Egészségtudományi Kar Pécs

4. Egészségtudományi Doktori Iskola, Pécsi Tudományegyetem, Egészségtudományi Kar Pécs

Abstract

Abstract: Introduction and aim: In case of imaging modalities using ionizing radiation, radiation exposure of the patients is a vital issue. It is important to survey the various dose-reducing techniques to achieve optimal radiation protection while keeping image quality on an optimal level. Method: We reprocessed 105 patients’ data prospectively between February and April 2017. The determination of the radiation dose was based on the effective dose, calculated by multiplying the dose-length product (DLP) and dose-conversation coefficient. In case of image quality we used signal-to-noise ratio (SNR) based on manual segmentation of region of interest (ROI). For statistical analysis, one sample t-test and Wilcoxon signed rank test were used. Results: Using iterative reconstruction, the effective dose was significantly lower (p<0.001) in both native and contrast-enhanced abdominal, contrast-enhanced chest CT scans and in the case of the total effective dose. At native and contrast-enhanced abdominal CT scans, the noise content of the images showed significantly lower (p<0.001) values for iterative reconstruction images. At contrast-enhanced chest CT scans there was no significant difference between the noise content of the images (p>0.05). Conclusion: Using iterative reconstruction, it was possible to achieve significant dose reduction. Since the noise content of the images was not significantly higher using the iterative reconstruction compared to the filtered back projection, further dose reduction can be achievable while preserving the optimal quality of the images. Orv Hetil. 2019; 160(35): 1387–1394.

Publisher

Akademiai Kiado Zrt.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3