Development and validation of RP HPLC method for the estimation of methyl paraben sodium and propyl paraben sodium in iron protein succinylate syrup

Author:

Javed Muhammad Faisal1,Zahra Manzar1ORCID,Javed Iqra2,Ahmad Shahbaz3,Jabeen Tayyaba4,Ahmad Muhammad5

Affiliation:

1. Department of Chemistry, Lahore Garrison University, Lahore, Pakistan

2. Lahore Pharmacy College, A Project of Lahore Medical & Dental College, Pakistan

3. Himont Parmaceuticals, Lahore, Pakistan

4. Department of Zoology, Quaid-i-Azam University, Islamabad, Pakistan

5. Department of Chemistry, Division of Science and Technology, University of Education, Lahore, 54770, Pakistan

Abstract

AbstractA new precise, selective and reliable reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the determination of Methyl paraben sodium (MPS) and Propyl paraben sodium (PPS) (preservatives) in Iron protein succinylate syrup. Optimized conditions were; Methanol: Water (65: 35) as mobile phase, UV/Vis detector at the wavelength of 254 nm and flow rate was set at 1.3 ml min−1. By applying the set of conditions, separation of components was carried out in less than 7 min for both the analytes. The method was validated according to International conference of Harmonization (ICH) guidelines and the analytical characteristic parameters of validation included specificity, limit of detection (LOD), limit of quantification, linearity, accuracy, precision and robustness were evaluated. The calibration curve was found to be linear in the range of 0.045 mg mL−1 to 0.075 mg mL−1 for Methyl paraben sodium and 0.015 mg mL−1 to 0.025 mg mL−1 for propyl paraben sodium with a correlation coefficient r2 > 0.999. Accuracy; reported as percentage recovery was found to be in the range of 98.71%–101.64% for Methyl paraben sodium and 99.85%–101.47% for Propyl paraben sodium at 80%, 100% and 120% concentration for both the analytes. The proposed method was found to be precise and robust when evaluated by variations in wavelength, mobile phase composition, temperature and analyst. The limit of detection (LOD) was found 0.001 mg mL−1 (3 ppm) for Methyl paraben sodium and 0.001 mg mL−1 (1 ppm) for Propyl paraben sodium.

Publisher

Akademiai Kiado Zrt.

Subject

General Chemistry

Reference37 articles.

1. Eur. Food Res. Technol.;Chu, Q.,2010

2. Martindale: the Complete Drug Reference;Sweetman, S. C.,2009

3. Electrophoresis;Boyce, M. C.,2001

4. Int. J. Res. Phytochemistry Pharmacol.;Mallika, J.,2014

5. Inventi Rapid Pharm. Pract.;Tade, R. S.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献