A beállítási biztonsági margó nagyságának meghatározása fej-nyak daganatok 2D-2D és 3D képvezérelt intenzitásmodulált sugárkezelése esetén

Author:

Kovács Péter12,Szita Evelin1,Schvarcz Kitti1,Kamu Szabolcs1,Kalincsák Judit2,Kovács Árpád13,Repa Imre23,Hadjiev Janaki2

Affiliation:

1. Képalkotó Diagnosztikai Tanszék, Pécsi Tudományegyetem, Egészségtudományi Kar Kaposvár

2. Dr. Baka József Diagnosztikai, Onkoradiológiai, Kutatási és Oktatási Központ, Somogy Megyei Kaposi Mór Oktató Kórház Kaposvár

3. Egészségtudományi Doktori Iskola, Pécsi Tudományegyetem, Egészségtudományi Kar Kaposvár, Szent Imre u. 14/B, 7400

Abstract

Abstract: Introduction: Image-guided intensity-modulated radiation therapy is essential for oncology treatment of head-and-neck cancer patients. Aim: MV-kV and CBCT modalities were compared in case of IGRT treatment for head-and-neck cancer patients. Setup error, setup margin (SM), imaging and evaluation times and imaging doses were analyzed. Method: Eight patients’ elective treatment was evaluated, 66 orthogonal MV-kV images and 66 CBCT series were acquired. Setup error measurement was based on bony manual image registration in three translational directions. Normality test and F-test were performed followed by the comparison with independent-samples T-test (p<0,05). The necessary target volume setup margin was calculated based on Van Herk’s equation. Imaging time and setup error determination time were measured. Imaging doses were estimated based on the literature. Results: No statistically significant difference was found between setup errors determined by MV-kV and CBCT (VRT: 0.5 mm, SD = 1.9 vs. 0.4 mm, SD = 2.1, p = 0.371; LNG: 0.2 mm, SD = 2.2 vs. –0.1 mm, SD = 2.2, p = 0.188; LAT: 0.2 mm, SD = 2.2 vs. 0.3 mm, SD = 2.1, p = 0.41). SM values were: VRT: 2.7 mm vs. 2.5 mm; LNG: 2.1 mm vs. 1.3 mm; LAT: 2.2 mm vs. 2.3 mm. Mean imaging time was 0.65 min (MV-kV) vs. 2.29 min (CBCT). Mean setup error determination time was 2.41 min for both modalities. Estimated imaging doses were 6.88 mGy (MV-kV) vs. 17.2 mGy (CBCT) per fraction. Conclusion: The bony anatomy derived image registration based translational setup error determination results in similar values either by MV-kV or by CBCT. Using 3 mm setup margin in all the directions might be adequate. Imaging time is less by MV-kV, significant difference in imaging doses did not appear. Using CBCT is generally suggested. MV-kV might be an alternative in case of need for shortened imaging time. Orv Hetil. 2018; 159(29): 1193–1200.

Publisher

Akademiai Kiado Zrt.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3