Author:
Hanafusa H.,Sumida S.,Takato N.
Abstract
AbstractWe describe the results of accelerated lifetests performed on silica-based planar lightwave circuit (PLC) devices. Specifically, we tested PLC splitter modules in damp heat environments with different temperatures and humidities. The time-to-failure data of the splitter samples were analyzed by using the Weibull distribution, and the shape parameter was derived as 1.77. Moreover, the temperature and humidity dependence of the median life e was analyzed by using the equationand the coefficients E and n were determined to be 1.49 eV and 3.70, respectively. The thirtyyear hazard rate is estimated to be less than 40 FIT for PLC splitter modules operating at 60°C/ 40% RH.
Publisher
Springer Science and Business Media LLC
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献