Abstract
AbstractThis paper reviews experimental data on stress- and electromigration (EM)-induced voiding in passivated Al- and AlSiCu-lines under different experimental conditions (thermal cycling, iso-thermal annealing without and with EM-current). The data are deduced from measured changes of average metal strain or stress and from in-situ observations in a transmission electron microscope. There are excellent correlations between corresponding data sets showing stress induced voiding during cycling and isothermal annealing without EM-current, but nearly no changes in stresses or void volume during EM-testing. The implications of these results on EM-modelling are discussed.
Publisher
Springer Science and Business Media LLC
Reference21 articles.
1. Real-Time Tem Studies of Electromigration in Submicron Aluminum Runners
2. 1. Sanchez J. E. and Reilly C. J. , this Symposium (K4.4);
3. Heinen D. , Thesis, RWTH Aachen and Reports of FZ-Jtilich, Jil-3435 (1997);
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献