Author:
Tan Cher Ming,Gan Zhenghao,Zhang Guan,Prasad Krishnamachar,Zhang Dao Hua
Abstract
AbstractIn the present work, a novel method is proposed to re-construct voids in passivated metal interconnections. In this method, the conventional SEM and EBIC systems are assembled and utilized without much modification. In principle, a constant current is applied to the metal interconnections while an electron beam is scanning and impinging upon the surface of the sample. The voltage at the terminals is monitored simultaneously during electron beam scanning. Resistance change, and hence voltage perturbation are expected when the electron beam approaches the defective area, caused by uneven electron beam heating (EBH) and heat transmission. Information on defects or voids is thus obtained by analyzing the voltage alteration. Finite element simulation showed that the recorded voltage perturbation is not dependent of the length of the interconnect, but a linear function of the void volume. Thus, the method is essentially useful as the metal length has increased tremendously in copper technology. In addition, it can provide the void size and depth, with the possibility to reconstruct the entire void shape in 3D.
Publisher