Author:
Megherhi M. H.,Dayton G. O.,Shrout T. R.,Mecholsky J. J.
Abstract
The effects of internal electrodes on the fracture properties of relaxor ferroelectric 0.9Pb(Mg1/3Nb2/3)O3–0.1PbTiO3 multilayer structures were studied. It was observed that the position of the first electrode layer from the surface is critical to the strength and toughness of the multilayer structure. Positioning the electrode close to the surface was found to enhance interaction with cracks which initiate on the multilayer surface. This interaction limits the effective crack length and therefore increases the fracture strength and effective toughness of the composite. Samples indented parallel to the electrodes exhibited higher fracture strengths and toughness than those indented perpendicular to the conducting layers. Both parallel and perpendicular orientations gave higher strength and toughness than the control specimens (without electrodes).
Publisher
Springer Science and Business Media LLC
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference49 articles.
1. Internal electrode piezoelectric ceramic actuator
2. Microstructure of Lead-Magnesium Niobate Ceramics
3. Residual stress effects in sharp contact cracking
4. 42 Gorton A. J. , Chen J. , Smith D. , and Harmer M. P. , Proc. of the 6th IEEE Int. Symp. on Applications of Ferroelectrics, 150–153 (1986).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献