Author:
Harker Robert M.,Chohollo Afiya H.
Abstract
ABSTRACTIdentical samples of uranium coupons were prepared and each exposed to hydrogen for different times (where this time is significantly less than a classically understood ‘induction time’). Samples were prepared from rolled depleted uranium stock: as-received oxide was removed on all surfaces and two faces (~12x12 mm) were polished to a sub-micron standard. Samples were individually taken through a Vacuum Thermal Pre-Treatment cycle from room temperature to 200°C to the reaction temperature (80°C) over 40 hours and subsequently exposed to 10 mbar O2 for 24 hours. After O2 was removed, the samples were exposed to hydrogen for pre-determined times of up to 48 minutes. Examination of the samples by Scanning Electron Microscopy (SEM) has, as expected, identified small features protruding from the surface believed to have been caused by sub-surface precipitation of UH3. In general these features are circular and isolated from each other, have a diameter of less than 3μm and appear as either ‘flat-topped’ or ‘domed’ morphology. In addition, longer time exposure samples show a predominance of ‘area attack’ where coalesced sub-surface precipitation appears to be confined to particular metal grains. X-Ray Diffraction (XRD) data show an increase in the quantity of UH3 with time.
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.