Author:
Martinella R.,Chevallard G.,Tosello C.
Abstract
ABSTRACTMechanically polished Ti6Al4V samples were implanted with 100 key nitrogen ions to a fluence of 5.1017 ions/cm2 at two different bulk tenneratures: 370°C and 470°C. Wear tests were carried out with a reciprocating slidina tribotester. Structural modifications and wear morphologies were studied by TEM and SEM. 370°C implanted sample showed the same wear behavior as unimplanted ones, while 470°C implanted sample showed better wear resistance because of a TiN hardened layer. Correlations- between microstructural modifications, wear behavior and mechanisms are reported: results agree with the delamination theory. Comparison with ion- and gas-nitrided samples are presented.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献