Author:
Wen Qingzhe,Clarke David R.
Abstract
AbstractWhen a metal conductor is driven by an AC current of frequency ω, its resistance will vary at a frequency 2ω, and a third harmonic voltage will be generated. If the conductor is also under a DC bias, a second harmonic voltage will arise as well. The magnitude of these harmonic voltages increases with damage because of nonlinear increases in the resistance caused by localized Joule heating. We use the harmonic technique to evaluate the damage in metal lines. The correlation between deliberately introduced defects of different sizes and the amplitude of the harmonic voltages has been studied experimentally. The harmonic technique shows higher damage sensitivity than the commonly used resistance method. Additionally, it has a better rejection to noise and resistance drifting.
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献