ABSTRACTIn the paper the development and usage of radiation detection systems based on room temperature semiconductors are described. The detection systems are intended for use by safeguards inspectors to verify nuclear material. Because of their high intrinsic efficiency, these detectors have advantages compared to classical germanium or Nal detectors. Several measurement tasks which cannot be handled in an optimum manner by using standard detectors have been solved. The main problem in the application of room temperature semiconductor detectors is the limitation in the availability of large detector volumes.
Publisher
Springer Science and Business Media LLC
Reference10 articles.
1. 8. Levai F. , Tikkinen J. , Tarvainen M. , Arlt R. , Report STUK A-97 (1990).
2. 7. Ivanov V. , Draft Report (1992) (unpublished).
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Cadmium Zinc Telluride Detectors for Safeguards Applications;Advanced Materials for Radiation Detection;2021-08-06
2. Nuclear Safeguards Verification Measurement Techniques;Handbook of Nuclear Chemistry;2011
3. A tomographic method for experimental verification of the integrity of spent nuclear fuel;Applied Radiation and Isotopes;2000-11
4. Electronics for high resolution spectroscopy with compound semiconductors;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;1996-10
5. Investigation of the behaviour of a mercuric iodide detector under unusual irradiation conditions;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;1996-10