Use of Handheld Ultrasound to Estimate Fluid Status of Hemodialysis Patients

Author:

Shrestha Sanjaya KumarORCID,Ghimire Anupam,Ansari Safiur Rahman,Adhikari Ashok

Abstract

Introduction: Accurate assessment of fluid status in hemodialysis patients presents a significant challenge. Nephrologists have long relied on dry weight estimation based solely on clinical parameters to decide the ultrafiltration volume for patients with end-stage kidney disease on dialysis. However, this method is far from accurate and many patients recurrently suffer from signs and symptoms of fluid overload or circulatory collapse from overaggressive ultrafiltration. Invasive methods such as measurement of central venous pressure cannot be used routinely. We evaluated the usefulness of inferior vena cava (IVC) diameter measured by handheld ultrasound in the estimation of fluid status in patients before and after hemodialysis. Materials and Methods: Clinical assessment included patients’ symptoms, weight, blood pressure, heart rate, and presence of edema before and after dialysis session. Dry weight was assessed based on the above parameters. Each patient underwent measurement of inferior vena cava before and after hemodialysis. The anteroposterior IVC diameter (IVCD) was measured 1.5 cm below the diaphragm in the hepatic segment in supine position during normal inspiration and expiration.Results:  Thirty hemodialysis patients (mean age 51.6±18.03 years) were evaluated in outpatient dialysis unit. Following hemodialysis mean IVCe (IVC diameter in expiration) decreased from 1.40±0.38 to 0.91±0.30 cm (p<0.001). Similarly, mean IVCi (IVC diameter in inspiration) decreased from 0.67±0.34 to 0.35±0.19 cm (p<0.001). Changes in IVCD were significantly correlated with alterations in body weight following dialysis (p<0.0001). The IVC collapsibility index (IVC-CI, per cent of change in IVC diameter in expiration vs. inspiration) increased significantly from 0.53±0.18 to 0.68±0.18 after dialysis (p=0.002). IVC diameter and IVC-CI clearly reflected alterations in fluid status. Regarding the clinical parameters of fluid status, following hemodialysis, mean heart rate increased from 81.17±5.21 beats per minute to 86.50±7.99, (p=0.003), systolic blood pressure increased from 148.67±26.36 mmHg to 155.00±28.50, (p=0.05), and diastolic blood pressure increased from 78.62±12.74 mmHg to 84.83±14.55, (p<0.001).Conclusions:  Our findings support the applicability of IVCD measurement and IVC-CI in the estimation of fluid status in end stage kidney disease patients on hemodialysis. The clinical parameters of fluid status including heart rate, systolic blood pressure, and diastolic blood pressure suggest that significant numbers of patients underwent excess ultrafiltration based on their traditional dry weight calculation. Thus, using IVC parameters before and during hemodialysis might give a better estimation of fluid status of the patient and guide the amount of ultrafiltration to be done. 

Publisher

Nepal Journals Online (JOL)

Subject

General Agricultural and Biological Sciences

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3