Outcomes of implantable collamer lens V4 and V4c for correction of high myopia – a case series

Author:

Karandikar Smita,Bhandari Vipul,Reddy Jagdeesh

Abstract

Objective: To evaluate the visual outcomes and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with centraflow technology) for correction of myopia. Materials and methods: A prospective, consecutive, comparative interventional case series of V4b and V4c ICL implantation done for correction of high myopia (>-6 diopter D) in patients unsuitable for laser vision correction. The outcome measures that were evaluated included preoperative and postoperative uncorrected distant visual acuity (UDVA), best spectacle corrected distant visual acuity (CDVA), endothelial cell count (ECC), presence of lens opacification, intraocular pressure (IOP) and ICL vaulting. A follow-up of upto 1 year was done. A questionnaire was given at the end of follow-up period. Results: A total of 30 eyes (24.56±4.8 years) underwent V4b ICL implantation (10 non-toric, 20 toric ICL-TICL) with intraoperative peripheral iridectomy (PI) and 34 eyes (26.13±3.8 years) had implantation of V4c ICL with centraflow (12 non-toric, 22 TICL). The mean preoperative manifest spherical equivalent (MSE) was 8.98±2.8 D and 9.24±2.4 D in the V4b and V4c groups respectively which reduced to postoperative values of -0.28±1.3 D and -0.19±1.18 D respectively. The mean preoperative astigmatism was -1.8±1.2 diopter cylinder (Dcyl) and -1.9±1.6 Dcyl which respectively reduced to -0.8±0.8 Dcyl and -0.9±0.3 Dcyl. At the end of 1 year follow up, mean ECC loss was 7.6% and 7.1%, mean vault was 583.12±231.12 μ and 602±241.24μ respectively in the V4b and V4c groups. Anterior subcapsular opacities were present in 6.66% and 2.94% of eyes with V4b and V4c groups respectively. Two eyes from both V4b (10%) and V4c (8.33%) had rotation of more than 30 degrees and required re-rotation surgery done successfully. Two eyes (6.66%) with V4b ICL implantation had high postoperative IOP (>35 mm Hg) and required Nd:Yag laser iridotomy later done with successful control of IOP. The safety indices were 1.12 and 1.15 and efficacy indices were 1.5 and 1.6 in the V4b and V4c groups respectively at the end of 1 year. The most common visual complaint was glare and haloes in 24% and 27% in the two groups respectively. However, they were not annoying enough to cause visual disability. Conclusions: Both V4b and V4c Visian ICL implantations are comparable in terms of visual outcome and safety profile for correction of high myopia. However, V4c ICL offers these advantages without the requirement of an additional PI. 

Publisher

Nepal Journals Online (JOL)

Subject

General Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3