Coronary Angiography and Percutaneous coronary Intervention in Anomalous Origin of Right Coronary Artery Arising from the Left Sinus of Valsalva

Author:

Poudel Chandra Mani,Gajurel Ratna Mani,Shrestha Hemant,Devkota Surya,Thapa Sanjeev,Khanal Rajaram,Shakya Smriti,Manandhar Bhawani,Yadav Vijay

Abstract

Background and Aims: To assess the difficulties encountered while performing coronary angiography and percutaneous coronary intervention in anomalous right coronary artery arising from the left sinus of Valsalva. Methods: Between January 2016 and December 2020, a total of 23 patients underwent coronary angiography and eight underwent percutaneous coronary intervention for an angiographic significant lesion in the anomalous right coronary artery arising from the left sinus of Valsalva. The vascular approach, usage of catheters, fluoroscopic time, and the amount of contrast used were also assessed. Results: Among 6000 coronary angiography and 1500 percutaneous coronary intervention performed, 33 patients (0.55%) had right coronary artery arising from the left sinus of Valsalva. Altogether, 14 patients had type-A, seven had Type-B, eight had Type-C, and four had Type-D anomalous right coronary artery arising from the left sinus of Valsalva. Coronary Angiography was accomplished with the Tiger catheter in 13 patients, Judkins left JL in 8 patients, and Extra-backup (XB3) in one patient. In the percutaneous coronary intervention group, cannulation was done with Judkins left (JL), Amplatz left (AL), and XB in five, two, and one patient respectively and among five type-A patients, four were cannulated with JL and one with XB; one Type-B with JL4; and two Type-C with AL2. The mean fluoroscopic time and contrast volume consumption for coronary angiography and percutaneous coronary intervention were 9.9 minutes and 47 minutes respectively and 63ml and 229 ml respectively. Conclusion: Coronary intervention of anomalous right coronary artery arising from the left sinus of Valsalva is difficult due to inappropriate selection of guide catheter and is associated with a higher both mean fluoroscopic time and contrast volume. Radial route is equally effective for successful procedure.

Publisher

Nepal Journals Online (JOL)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3