Incidence and Severity of Postdural Puncture Headache following Subarachanoid Block using 25G Quincke and 25G Whitacre Spinal Needles: A Double-blinded, Randomised Control Study

Author:

Balusamy Devanathan,Khoirom Surmila,Charan Nameirakpam,Nahakpam Sonia,Devi Ningombam Joenna,Divyabharathi Srinivasan,Devi Laishram Rani,Ali Mohd Ayub

Abstract

Introduction: Postdural Puncture Headache (PDPH) is the most common complication of dural puncture. Clinical studies have shown that use of small guage needles with pencil point tip is associated with lower incidence and severity of PDPH than with cutting tip needles. Aim: To compare the incidence and severity of PDPH between 25G cutting (Quincke) and 25G non cutting (Whitacre) needles. Materials and Methods: In this randomised controlled study conducted at Jawaharlal Nehru Institute of Medical SciencesImphal, Manipur, India from September 2019 to September 2021. A total of 150 patients of both sexes, age <60 years and American Society of Anaesthesiologists (ASA) grade I and II, undergoing lower abdominal or lower limb surgeries under spinal anaesthesia were enrolled for this study and divided into two groups with 75 patients in each group. Spinal anaesthesia was performed with 25G Quincke needle in one group and 25G Whitacre needle used in other group to compare the incidence and severity of PDPH (severity was determined by limitation of patient activity and treatment required). Results: Overall 14 patients (9.33%) developed PDPH – 2 in the Whitacre spinal needle (2.6%), and 12 in the Quincke spinal needle (16%), with p-value of 0.009. The incidence of failed spinal anaesthesia was significantly higher with Whitacre spinal needle 12 (16%) than with Quincke needle 4 (5.3%), with p-value of 0.03. Incidence of PDPH was more in female patients 12 (14.8%) compared with male patients 2 (2.9%),with p-value of 0.018. Severity of PDPH ranged from mild (n=10) to moderate (n=2) in Quincke needle group, whereas in Whitacre group patients had only mild form of PDPH (n=2). Conclusion: Incidence and severity of PDPH was significantly lower in 25G Whitacre spinal needle than 25G Quincke needle. Failure rate of spinal anaesthesia was more in Whitacre needle than in Quincke needle.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3