Evaluation of Doses to Target Volume and Organs at Risk by Conventional versus RTOG Contouring Based 3D Conformal Plans in Breast Cancer: A Prospective Study

Author:

Verma Prabha,Rastogi Madhup,Gandhi Ajeet Kumar,Khurana Rohini,Srivastava Anoop Kumar,Bharati Avinav,Hadi Rahat,Agarwal Niraj

Abstract

Introduction: In radiotherapy, conventional field borders have often little anatomical correlation with the draining lymphatics. So, with the availability of more conformal techniques and delineation guidelines, an evident need exists to optimise our treatment plans with more focus on planning and dosimetric aspects. Aim: To evaluate the differences in dosimetric parameters to the Organs at Risk and target volumes in patients treated with conventional plans vis-à-vis Radiation Therapy Oncology Group contour guided treatment plans. Materials and Methods: A prospective interventional study was conducted in which 30 patients of histopathologically proven Infiltrating Ductal Carcinoma (IDC) breast, with age range of 18 to 80 years were enrolled. Patients were treated with 50 Gray in 25 fractions of radiation with additional 10 Gray in 5 fractions boost in Breast Conserving Surgery (BCS) patients by conventional treatment plans. Radiation Therapy Oncology Group (RTOG) guidelines were used for breast/Chest Wall (CW), axillary nodes, Supraclavicular Fossa (SCF), and Internal Mammary Node (IMN) delineation. Organs At Risk (OARs) included heart, Ipsilateral (I/L) lung, Contralateral (C/L) breast, oesophagus and spinal cord. Dose-Volume Histograms (DVHs) for these contours were generated from conventional treatment plans. Further, new treatment plans were generated to cover >90% of Planning Target Volume (PTV) by 90% isodose line. DVH parameters of these two plans were compared using paired t-test. A p-value of <0.05 was considered statistically significant. Results: Of the total 30 cases, the mean volume of breast/CW PTV covered by 90% isodose line (V90) was better in RTOG plan as compared to Conventional plan (93.39 vs 90.39, p-value=0.001). Similarly, mean V90 for total axilla (97.44 vs 90.39, p-value=0.0001) and combined PTV (92.60 vs 88.81, p-value=0.0001) was better with RTOG plan. For OARs, conventional vs RTOG plans; Dmean for heart was 2.56 vs 2.60Gy, p-value=0.63), I/L lung V20Gy was 28.77 vs 28.94%, p-value=0.71) and V5Gy for C/L breast was 0.48 vs 0.54%, p-value=0.47), respectively. In cases where IMN was irradiated, mean doses to the heart, I/L lung V20Gy, and contralateral breast V5Gy increased significantly. Conclusion: The present study showed that RTOG target volumes had inadequate coverage in conventional plans. On the contrary, plans directed at RTOG contours provided statistically better coverage for target volumes without increase in the doses to the OARs. In patients with IMN irradiation, the doses to some OARs were increased in RTOG as compared to conventional plans.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3