A Comparative Evaluation of Dimensional Accuracy and Surface Detail Reproduction for Polyvinyl Siloxane and Vinyl Siloxane Ether under Dry and Moist Conditions- An In-vitro Study

Author:

Pokharkar Amit Baban,Palekar Umesh Gopal,Saraf Veena,Vikhe Deepak Machindra,Bhiwapurkar Shefali Sevakram,Madanshetty Pallavi

Abstract

Introduction: The conventional impression procedure plays a major role in prosthodontics inspite of advancement in intra- oral scanning devices and 3D imaging procedures. Dimensional accuracy and surface detail reproduction are important for recording an impression. Aim: The study evaluated and compared the dimensional accuracy and surface detail reproduction of Polyvinyl Siloxane (PVS) and vinyl siloxane ether impression materials when used under dry and moist conditions. Materials and Methods: An in-vitro study was conducted in the Department of Prosthodontics, Rural Dental College, Pravara Institute of Medical Sciences, Loni, Ahmednagar, Maharashtra, India, for a period of two years from October 2018 to September 2020. A total of 60 impressions were made with PVS (Group A) and vinyl siloxane ether (Group B) under dry (A1, B1) and moist (A2, B2) conditions of stainless steel dies which had lines engraved on superior surface of the die. Using a Harloc’s Tool maker’s microscope, dimensional accuracy was measured by comparing the width of line Y in each impression. Surface detail reproduction was evaluated by American Dental Association (ADA) specification no. 19 where it stated continuous replication of at least any two lines out of the three lines inscribed on the die. Data analysis processing was performed in the SYSTAT version 12 (made by Crane’s software, Bangalore). Student’s unpaired t-test and Chi-square test were performed to determine statistical difference between PVS and vinyl siloxane ether where the level of significance was set at 5% and 1%. Results: The mean dimensional change and SD values for PVS under dry condition ranged from 21.93±2.46 to 22.40±2.89 (in mm). The mean dimensional change and SD values for PVS under moist condition ranged from 22.87±3.20 to 23.33±3.42. The mean dimensional change and SD values for vinyl siloxane ether under dry condition ranged from 21.93±3.61 to 24.73±5.20. The mean dimensional change and SD values for vinyl siloxane ether under moist condition ranged from 21.93±4.48 to 22.87±4.15. No statistical difference was found under dry and moist conditions within 2 hours and after 24 hours for both the materials. Conclusion: The study revealed no significant difference between dimensional accuracy and surface detail reproduction for PVS and vinyl siloxane ether. Both the materials can reproduce the details under dry and moist conditions satisfactorily and remained dimensionally stable till 24 hours after impression making.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3