Comparison of Primary Stability of Two Different Implants DesignsA Prospective Clinical Study

Author:

Sravanthi A Veena,Manne Prakash,Surapaneni Haragopal

Abstract

Introduction: Any implant treatment must begin with successful implant integration. The effectiveness of implant osseointegration is determined by various factors, including implant design, implant diameter and density, and surgical technique. Osseointegration is dependent on implant design. Aim: To assess the primary stability of tapered and cylindrical implants by using Resonance Frequency Analysis (RFA) and Insertion Torque Values (ITV). Materials and Methods: This in-vivo, prospective clinical study was conducted in the Department of Prosthodontics at Sibar Institute of Dental Sciences, Guntur, Andhra Pradesh, India in the month of November 2019. Twenty patients were selected for the study. Tapered Bioline implants (Bioline Dental GmbH & Co. KGGermany) were spaced in 10 patients (group 1) and cylindrical Bioline implants (Bioline Dental GmbH & Co. KG-Germany) in the other 10 patients (group 2). For both implant designs, primary stability was assessed immediately after implant placement using RFA by Osstell Mentor and ITV by a torque wrench. KolmogorovSmirnov test, Shapiro-Wilk test were used for checking normality. Mann Whitney U test, Independent t tests, Spearman correlation tests were done by using software Statistical Package for Social Sciences (SPSS) Version 23.0. Results: The mean ISQ (Implant Stability Quotient) for tapered implants was 76.6±2.3, and for cylindrical implants mean ISQ is 59.75±4.2 (p-value <0.001). The mean ITV for tapered implants was 43.5±2.58 Ncm, and for cylindrical implants, the mean ITV was 33±4.21 Ncm (p-value <0.001). The correlation between ITV and RFA was 0.928 which was highly significant (p<0.001**). Conclusion: Within the scope of this investigation, tapered implants showed better primary stability than cylindrical-shaped implants as determined by ISQ and insertion torque values. ITV and ISQ values showed a positive correlation in determining the primary stability of implants.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3