Correlation of Six Minute Walking Test, Sit to Stand Test and Pulmonary Function Test in Patients with Chronic Obstructive Pulmonary Disease

Author:

Meghashri V,Raveesha A,. Guruprasad,Mehta Charchit,Deepthi Manchu

Abstract

Introduction: Assessment of functional capacity in Chronic Obstructive Pulmonary Disease (COPD) patients helps in determining the severity of the disease. While spirometry is the gold standard, six Minutes Walk Test (6MWT) and one minute Sit To Stand Test (STST) are simple and practical tests to assess exercise capacity and physical condition. Aim: To find the diagnostic accuracy of these of 6MWT and one minute STST in comparison with spirometry. Materials and Methods: This cross-sectional study was conducted in the Department of General Medicine at Sri Devaraj Urs Academy of Higher Education and Research, Kolar, Karnataka, India, from January 2019 to December 2019. All cases of COPD diagnosed using GOLD 2018 criteria were included in the study. Patients performed 6MWT and one minute STST. Heart rate, blood pressure, oxygen saturation, SpO2, dyspnea, and fatigue (Borg scale) were noted pretest and posttest. The sensitivity, specificity, predictive values and diagnostic accuracy of the screening test with the decided cut-off values along with their 95% CI were presented. A p-value<0.05 was considered statistically significant. Results: The mean age of the patients was 64.09±8.31,while there were 112 (94.9%) males and 6 (5.1%) female. Overall, 81.54% of the participants had severe/very severe COPD group, walked <332.49 meters, and only 18.46% could walk more than 332.50 m. SpO2 decreased from 93.98±0.82 to 91.75±1.39. During the one minute STST SpO2 decreased from 93.98±0.82 to 91.75±1.39. A positive correlation was observed between the one minute STST, and it had good predictive validity in predicting COPD as compared with spirometry (area under the curve of 0.915 95% CI 0.866 to 0.963, p-value <0.001). 6MWT has a sensitivity of 81.54%, the specificity of 79.25%, and one minute STST had a sensitivity of 89.23%, specificity of 67.92% in predicting COPD. Conclusion: In a remote clinical setting where spirometry is not available, 6MWT and one minute STST are the best methods for assessing COPD severity.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3