C-MAC D-Blade vs Airtraq for Intubation with Manual Inline Axial Stabilisation- A Randomised Clinical Trial

Author:

Mani Nikitha,Palanisamy Nagalakshmi,Zachariah Mamie,George Sagiev Koshy,Dsilva Allen Aloysius,Johns Jemmie Rachel

Abstract

Introduction: One of the most important skills in anaesthesia is securing the airway with an endotracheal tube. Difficult tracheal intubation however is considered one of the major contributors of anaesthesia related morbidity and mortality. Video laryngoscopy offers several advantages during endotracheal intubation. The view of the glottis provided by Videolaryngoscopes is better compared to the Macintosh laryngoscope in difficult airways which makes it more attractive for routine difficult airway intubations. Aim: To compare the time taken for intubation between two Videolaryngoscopes, namely C-MAC D-blade and Airtraq and to assess the quality of laryngoscopy view between the two groups. Materials and Methods: This was a randomised clinical trial conducted in 116 American Society of Anesthesiologists 1 (ASA1) and ASA2 patients undergoing elective surgeries in Pondicherry Institute of Medical Sciences. Patients are randomised into two groups, Group C-MAC D-blade and Group Airtraq by computer randomisation. Statistical analysis was performed using t-test, Repeated measures of ANOVA was used to find the significance from preinduction to 10 mins period for each group and Bonferoni’s correction for intergroup comparison. Results: The time taken for intubation was comparable in two study groups (Group C-MAC D-blade 41.88 secs) and (Group Airtraq -40.78 sec) with p-value of 0.734. Laryngoscopic view was not statistically significant with p-value of 0.083. Optimisation maneuvers were required in 63.8% in Group Airtraq on comparison with 44.8% in Group C-MAC D-blade. In both Group C-MAC D-blade and Group Airtraq, there was a significant rise in the heart rate and BP at 0 minute compared to preinduction. But after 5 minutes, the heart rate and BP were back to preinduction values. Conclusion: Both the Videolaryngoscopes, C-MAC D-blade and Airtraq performed equally, with respect to time taken for intubation and laryngoscopic view. However, External Laryngeal Manipulation (ELM) was required more in Group Airtraq and was statistically significant.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3